variable speed drive ATV61 - 45kW / 690V - 50HP / 575V - IP20

Tehnične lastnosti

Glavno
Serija izdelkaAltivar 61
Izdelek ali sestavni delvariable speed drive
[Us] Nazivna napajalna npetost500...690 V - 15...10 %
product specific applicationpumping and ventilation machine
network number of phases3 phases
component nameATV61
line current51 A for 600 V 3 phases 37 kW / 50 hp 55 A for 690 V 3 phases 37 kW / 50 hp 62 A for 500 V 3 phases 37 kW / 50 hp
asynchronous motor control profilevoltage/frequency ratio, 5 points voltage/frequency ratio, 2 points voltage/frequency ratio - Energy Saving, quadratic U/f flux vector control without sensor, standard
motor power kW37 kW, 3 phases at 500 V 45 kW, 3 phases at 690 V
switching frequency2.5...4.9 kHz adjustable 2.5...4.9 kHz with derating factor
maximum transient current70.8 A for 60 s, 3 phases
assembly stylewith heat sink
nominal switching frequency2.5 kHz
EMC filterLevel 3 EMC filter
type of polarizationno impedance for Modbus
motor power hp50 hp, 3 phases at 575 V
prospective line Isc22 kA for 3 phases
communication port protocolCANopen Modbus
option cardcommunication card for APOGEE FLN communication card for LonWorks communication card for METASYS N2 communication card for Modbus Plus communication card for Modbus TCP communication card for Modbus/Uni-Telway multi-pump card communication card for Profibus DP communication card for Profibus DP V1 communication card for BACnet communication card for CC-Link controller inside programmable card communication card for DeviceNet communication card for Ethernet/IP communication card for Fipio I/O extension card communication card for Interbus-S
synchronous motor control profilevector control without sensor, standard
Komplementarno
network frequency47.5...63 Hz
Višina630 mm
Teža izdelka68 kg
local signalling1 LED (red)drive voltage:
Širina320 mm
Globina290 mm
tightening torque0.6 N.m (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR) 41 N.m, 360 lb.in (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
Omejitve napajalne napetosti425-759 V
protection typeagainst exceeding limit speed: drive power removal: drive short-circuit between motor phases: drive thermal protection: drive motor phase break: motor power removal: motor thermal protection: motor against input phase loss: drive break on the control circuit: drive input phase breaks: drive line supply overvoltage: drive line supply undervoltage: drive overcurrent between output phases and earth: drive overheating protection: drive overvoltages on the DC bus: drive
operating positionvertical +/- 10 degree
output voltage<= power supply voltage
electrical connectionterminal 2.5 mm² / AWG 14 (AI1-/AI1+, AI2, AO1, R1A, R1B, R1C, R2A, R2B, LI1...LI6, PWR) terminal 150 mm² / 300 kcmil (L1/R, L2/S, L3/T, U/T1, V/T2, W/T3, PC/-, PO, PA/+, PA, PB)
OznačevanjeCE
transmission rate4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus on terminal 9600 bps, 19200 bps for Modbus on front face 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen
type of cablewith an IP21 or an IP31 kit: 3 wire(s)IEC cable at 40 °C, copper 70 °C / PVC with UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR
insulation resistance> 1 mOhm 500 V DC for 1 minute to earth
supply frequency50...60 Hz - 5...5 %
accuracy+/- 0.6 % (AI1-/Al1+) for a temperature variation 60 °C +/- 0.6 % (AI2) for a temperature variation 60 °C +/- 1 % (AO1) for a temperature variation 60 °C
maximum switching currentR1, R2: 2 A at 250 V AC inductive load, cos phi = 0.4 and L/R = 7 ms R1, R2: 2 A at 30 V DC inductive load, cos phi = 0.4 and L/R = 7 ms R1, R2: 5 A at 250 V AC resistive load, cos phi = 1 and L/R = 0 ms R1, R2: 5 A at 30 V DC resistive load, cos phi = 1 and L/R = 0 ms
discrete output typeconfigurable relay logic: (R1A, R1B, R1C) NO/NC - 100000 cycles configurable relay logic: (R2A, R2B) NO - 100000 cycles
response time <= 100 ms in STO (Safe Torque Off) R1A, R1B, R1C <= 7 ms, tolerance +/- 0.5 ms R2A, R2B <= 7 ms, tolerance +/- 0.5 ms
discrete input logicnegative logic (sink) (LI1...LI5), > 16 V (state 0), < 10 V (state 1) positive logic (source) (LI1...LI5), < 5 V (state 0), > 11 V (state 1) negative logic (sink) (LI6)if configured as logic input, > 16 V (state 0), < 10 V (state 1) positive logic (source) (LI6)if configured as logic input, < 5 V (state 0), > 11 V (state 1)
product destinationasynchronous motors synchronous motors
acceleration and deceleration rampsautomatic adaptation of ramp if braking capacity exceeded, by using resistor S, U or customized linear adjustable separately from 0.01 to 9000 s
analogue output typeAO1 software-configurable current, analogue output range 0...20 mA, impedance: 500 Ohm, resolution 10 bits AO1 software-configurable voltage, analogue output range 0...10 V DC, impedance: 470 Ohm, resolution 10 bits AO1 software-configurable logic output 10 V, 20-20 mA
physical interface2-wire RS 485 for Modbus
transient overtorque130-130 % of nominal motor torque +/- 10 % for 60 s
torque accuracy+/- 15 % in open-loop mode, without speed feedback
data format8 bits, 1 stop, even parity for Modbus on front face 8 bits, odd even or no configurable parity for Modbus on terminal
frequency resolutionanalog input: 0.024/50 Hz display unit: 0.1 Hz
connector type1 RJ45 (on front face) for Modbus 1 RJ45 (on terminal) for Modbus male SUB-D 9 on RJ45 for CANopen
analogue input number2
motor slip compensationcan be suppressed automatic whatever the load adjustable not available in voltage/frequency ratio (2 or 5 points)
discrete output number2
regulation loopfrequency PI regulator
transmission frameRTU for Modbus
analogue output number1
minimum switching current3 mA at 24 V DC for configurable relay logic
method of accessslave CANopen
speed range1-100 in open-loop mode, without speed feedback
discrete input number7
linearity error+/- 0.15 % of maximum value (AI1-/Al1+) +/- 0.15 % of maximum value (AI2) +/- 0.2 % (AO1)
number of addresses1-127 for CANopen 1-247 for Modbus
braking to standstillby DC injection
discrete input typeprogrammable (LI1...LI5)24 V DC (<= 30 V), with level 1 PLC - 3500 Ohm switch-configurable (LI6)24 V DC (<= 30 V), with level 1 PLC - 3500 Ohm switch-configurable PTC probe (LI6)0-6 probes - 1500 Ohm safety input (PWR)24 V DC (<= 30 V) - 1500 Ohm
analogue input typeAI1-/Al1+ bipolar differential voltage: +/- 10 V DC 24 V max, resolution 11 bits + sign AI2 software-configurable current: 0...20 mA, impedance: 242 Ohm, resolution 11 bits AI2 software-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 11 bits
supplyinternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC, +/- 5 %, <10 mA with overload and short-circuit protection internal supply: 24 V DC (21-27 V), <200 mA with overload and short-circuit protection external supply: 24 V DC (19-30 V)
braking torque<= 125 % with braking resistor 30 % without braking resistor
speed accuracy+/- 10 % of nominal slip 0.2 Tn to Tn without speed feedback
sampling duration2 ms +/- 0.5 ms (AI1-/Al1+) - analog input 2 ms +/- 0.5 ms (Al2) - analog input 2 ms +/- 0.5 ms (AO1) - analog output 2 ms +/- 0.5 ms (LI1...LI5) - discrete input 2 ms +/- 0.5 ms (LI6)if configured as logic input - discrete input
isolationbetween power and control terminals
continuous output current52 A at 2.5 kHz, 575 V - 3 phases 54 A at 2.5 kHz, 690 V - 3 phases 59 A at 2.5 kHz, 500 V - 3 phases
output frequency0.1-500 Hz
Okolje
Temperatura okoliškega zraka za delovanje-10-50 °C (without) 50-60 °C (with derating factor)
IP stopnja zaščiteIP20 on upper part without blanking plate on cover conforming to EN/IEC 60529 IP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1 IP21 conforming to EN/IEC 60529 IP21 conforming to EN/IEC 61800-5-1 IP41 on upper part conforming to EN/IEC 60529 IP41 on upper part conforming to EN/IEC 61800-5-1 IP54 on lower part conforming to EN/IEC 60529 IP54 on lower part conforming to EN/IEC 61800-5-1
Stopnja onesnaženosti3 conforming to EN/IEC 61800-5-1 3 conforming to UL 840
Temperatura okoliškega zraka za skladiščenje-25-70 °C
relative humidity5-95 % without condensation conforming to IEC 60068-2-3 5-95 % without dripping water conforming to IEC 60068-2-3
Nadmorska višina delovanja<= 1000 m without 1000...2260 m with current derating 1 % per 100 m
Certifikati izdelkovGOST NOM 117 UL DNV C-Tick CSA
StandardiEN 61800-3 environments 1 category C3 EN/IEC 61800-3 EN 61800-3 environments 2 category C3 EN 55011 class A group 2 EN/IEC 61800-5-1 IEC 60721-3-3 class 3C2 UL Type 1
Odporno proti udarcu15 gn for 11 ms conforming to EN/IEC 60068-2-27
Odpornost proti vibracijam1 gn (f= 13-200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm peak to peak (f= 3-13 Hz) conforming to EN/IEC 60068-2-6
Elektromagnetna kompatibilnostconducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 voltage dips and interruptions immunity test conforming to IEC 61000-4-11
dielectric strength3110 V DC between earth and power terminals 5345 V DC between control and power terminals
noise level63.7 dB conforming to 86/188/EEC