Opis

liquid level control relay RM35-L - 24..240 V AC/DC

Tehnične lastnosti

Glavno
Serija izdelkaZelio Control
Izdelek ali sestavni delmodular measurement and control relays
utilisation categoryAC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1
time delay typeadjustable 0.1...5 s, +/- 10 %
measurement range250 Ohm...1 MOhm
switching capacity in VA1250 VA
relay nameRM35L
relay typelevel control relay
relay monitored parametersdetection by resistive probes
minimum switching current10 mA at 5 V DC
maximum switching current5 A AC/DC
maximum power consumption in VA5 VA AC
Komplementarno
mounting support35 mm symmetrical DIN rail conforming to EN/IEC 60715
Povezave - terminaliscrew terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end
[Ui] Nazivna izolacijska trdnost250 V conforming to IEC 60664-1
electrical durability100000 cycles
mechanical durability30000000 cycles
Kompatibilnostna kodaRM3
local signallingLED (yellow)relay ON: LED (green)power ON: LED (yellow)timer ON:
Širina35 mm
tightening torque0.6-1 N.m conforming to IEC 60947-1
[Us] rated supply voltage24...240 V AC/DC 50/60 Hz +/- 10 %
Omejitve napajalne napetosti20.4-264 V AC/DC
operating positionany position without
housing materialself-extinguishing plastic
OznačevanjeCE : 73/23/EEC CE : EMC 89/336/EEC
repeat accuracy+/- 2 % for time delay
insulation resistance> 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5 > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1 > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5 > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1 > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5 > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1
safety reliability dataB10d = 170000 MTTFd = 182.6 years
overvoltage categoryIII conforming to IEC 60664-1
measurement accuracy+/- 10 % of the full scale value +/- 20 % for the HS range
Omejitve napetosti regulacijskega vezja- 15 % + 10 % Un
maximum switching voltage250 V AC/DC
maximum power consumption in W1.5 W DC
nominal output current5 A
reset time1750 ms
functionalityresistive probe detection
operating rate<= 360 operations/hour full load
maximum cable distance between devices100 m
measurement error0.5 %/°C with temperature variation
output contacts2 C/O
run-up delay at power-up0.6 s
sensitivity scale0.25...5 kOhm LS (Low Sensitivity) 5...100 kOhm St (Standard Sensitivity) 50...1000 kOhm HS (High Sensitivity)
cable capacitance1 nF at HS (High Sensitivity) for probe cable 2.2 nF at St (Standard Sensitivity) for probe cable 4.7 nF at LS (Low Sensitivity)
maximum supply current for sensors1 mA
sensitivity adjustment5-100 %
Okolje
Temperatura okoliškega zraka za delovanje-20-50 °C
IP stopnja zaščiteIP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529
Stopnja onesnaženosti3 conforming to IEC 60664-1
Temperatura okoliškega zraka za skladiščenje-40-70 °C
relative humidity95-95 % at 55-55 °C conforming to IEC 60068-2-30
Certifikati izdelkovCSA GL UL C-Tick GOST
StandardiEN/IEC 60255-6
Odporno proti udarcu15 gn for 11 ms conforming to IEC 60255-21-1
Odpornost proti vibracijam0.35 mm (f= 5-57.6 Hz) conforming to IEC 60068-2-6 1 gn (f= 57.6-150 Hz) conforming to IEC 60255-21-1
Elektromagnetna kompatibilnostemission standard for industrial environments conforming to EN/IEC 61000-6-4 emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 immunity for industrial environments conforming to NF EN/IEC 61000-6-2
immunity to microbreaks100 ms DC 90 ms AC
dielectric test voltage2 kV, 1 min AC 50 Hz conforming to IEC 60255-5 2 kV, 1 min AC 50 Hz conforming to IEC 60664-1