frequency control relay RM35-HZ - range 40..70 Hz

Tehnične lastnosti

Glavno
Serija izdelkaZelio Control
Izdelek ali sestavni delmodular measurement and control relays
utilisation categoryAC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 DC-14 conforming to IEC 60947-5-1
time delay typeadjustable 0.1...10 s, +/- 10 % on crossing the threshold
measurement range40...70 Hz frequency
switching capacity in VA1250 VA
relay nameRM35HZ21FM
relay typefrequency control relays
relay monitored parametersoverfrequency and underfrequency 50 or 60 Hz
minimum switching current10 mA at 5 V DC
maximum power consumption in VA6 VA AC
Komplementarno
mounting support35 mm symmetrical DIN rail conforming to EN/IEC 60715
Povezave - terminaliscrew terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
[Ui] Nazivna izolacijska trdnost400 V conforming to IEC 60664-1
electrical durability100000 cycles
mechanical durability30000000 cycles
Kompatibilnostna kodaRM3
Širina35 mm
tightening torque0.6-1 N.m conforming to IEC 60947-1
[Us] rated supply voltage120...277 V AC 120...277 V AC
Omejitve napajalne napetosti102-308 V AC
contacts materialcadmium free
operating positionany position without
housing materialself-extinguishing plastic
OznačevanjeCE : 73/23/EEC CE : EMC 89/336/EEC
repeat accuracy+/- 0.5 % for input and measurement circuit +/- 0.5 % for time delay
status LED1 LED green for power ON 1 LED yellow for correct frequency (high R1) 1 LED yellow for correct frequency (low R2)
insulation resistance> 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5 > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1 > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5 > 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1 > 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5 > 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1
insulationno galvanic insulation between supply and measurement
supply frequency50/60 Hz +/- 10 %
overvoltage categoryIII conforming to IEC 60664-1
measurement accuracy+/- 10 % of the full scale value in input +/- 10 % of the full scale value in time delay
Omejitve napetosti regulacijskega vezja- 15 % + 10 % Un
maximum switching voltage250 V AC/DC
hysteresis0.3-0.3 % fixed
nominal output current5 A
reset time2000 ms time delay
operating rate<= 360 operations/hour full load
maximum measuring cycle200 ms measurement cycle as true rms value
measurement error+/- 0.05 %/°C with temperature variation < +/- 1 % over the whole range with voltage variation
output contacts1 C/O + 1 C/O
threshold setting-2...10 Hz -10...2 Hz
run-up delay at power-up0.5 s
control circuit frequency40...70 Hz
input frequency70 Hz
Okolje
Temperatura okoliškega zraka za delovanje-20-50 °C
IP stopnja zaščiteIP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529
Stopnja onesnaženosti3 conforming to IEC 60664-1
Temperatura okoliškega zraka za skladiščenje-40-70 °C
relative humidity95-95 % at 55-55 °C conforming to IEC 60068-2-30
Certifikati izdelkovGL UL CSA C-Tick GOST
StandardiIEC 60255-6 NF EN 60255-6
Odporno proti udarcu15 gn for 11 ms conforming to IEC 60255-21-1
Odpornost proti vibracijam0.35 mm (f= 5-57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1 1 gn (f= 57.6-150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
Elektromagnetna kompatibilnostemission standard for industrial environments conforming to EN/IEC 61000-6-4 emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 immunity for industrial environments conforming to NF EN/IEC 61000-6-2
non-dissipating shock wave4 kV
immunity to microbreaks10 ms
dielectric test voltage2 kV AC 50 Hz