multifunction control relay RM17-TT - range 183..528 V AC

Tehnične lastnosti

Glavno
Serija izdelkaZelio Control
Izdelek ali sestavni delmodular measurement and control relays
product specific applicationfor 3-phase supply
time delay typewithout
measurement range208...480 V voltage AC
switching capacity in VA1250 VA
relay nameRM17TT
relay typemultifunction control relay
relay monitored parametersphase failure detection phase sequence
Komplementarno
mounting support35 mm symmetrical DIN rail conforming to EN/IEC 60715
Teža izdelka0.13 kg
Povezave - terminaliscrew terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
[Ui] Nazivna izolacijska trdnost400 V conforming to IEC 60664-1
electrical durability100000 cycles
mechanical durability30000000 cycles
Kompatibilnostna kodaRM17
local signallingLED (green)power ON: LED (yellow)relay ON:
Širina17.5 mm
tightening torque0.6-1 N.m conforming to IEC 60947-1
Omejitve napajalne napetosti183-528 V AC
operating positionany position without
housing materialself-extinguishing plastic
OznačevanjeCE
repeat accuracy0.5 % for input and measurement circuit 3 % for time delay
insulation resistance> 500 MOhm at 500 V DC conforming to IEC 60255-5 > 500 MOhm at 500 V DC conforming to IEC 60664-1
power consumption in VA0-22 VA at 400 V AC 50 Hz
safety reliability dataMTTFd = 502.2 years B10d = 470000
supply frequency50/60 Hz +/- 10 %
overvoltage categoryIII conforming to IEC 60664-1
maximum switching current5 A AC 5 A DC
response time< 200 ms (in the event of a fault)
minimum switching current10 mA at 5 V DC
Omejitve napetosti regulacijskega vezja- 12 % + 10 % Un
maximum switching voltage250 V AC 250 V DC
phase failure sensitivity0.7 Un
utilisation categoryAC-12 conforming to IEC 60947-5-1 AC-13 conforming to IEC 60947-5-1 AC-14 conforming to IEC 60947-5-1 AC-15 conforming to IEC 60947-5-1 DC-12 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1
hysteresis2-2 %
nominal output current5 A
voltage range208...480 V phase to phase
reset time1500 ms time delay
operating rate<= 360 operations/hour full load
maximum measuring cycle150 ms measurement cycle as true rms value
measurement error< 0.05 %/°C with temperature variation < 1 % over the whole range with voltage variation
output contacts1 C/O
run-up delay at power-up650 ms
control circuit frequency50...60 Hz +/- 10 %
adjustment of asymmetry threshold5...15 % of Un selected
threshold adjustment voltage-2...-17 % in the range 220 V AC 2...20 % of Un selected +2...+17 % in the range 480 V AC -2...-12 % in the range 208 V AC
measurement voltage limits183-528 V AC
Okolje
Temperatura okoliškega zraka za delovanje-20-50 °C
IP stopnja zaščiteIP20 (terminals) conforming to IEC 60529 IP30 (casing) conforming to IEC 60529
Stopnja onesnaženosti3 conforming to IEC 60664-1
Temperatura okoliškega zraka za skladiščenje-40-70 °C
relative humidity95-95 % at 55-55 °C conforming to IEC 60068-2-30
Certifikati izdelkovUL GL C-Tick GOST CSA
StandardiEN/IEC 60255-1
Odporno proti udarcu15 gn for 11 ms conforming to IEC 60255-21-1
Odpornost proti vibracijam0.35 mm (f= 5-57.6 Hz) conforming to IEC 60068-2-6 1 gn (f= 57.6-150 Hz) conforming to IEC 60255-21-1
Elektromagnetna kompatibilnostemission standard for industrial environments conforming to EN/IEC 61000-6-4 emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3 immunity for industrial environments conforming to EN/IEC 61000-6-2
directives73/23/EEC - low voltage directive 89/336/EEC - electromagnetic compatibility
non-dissipating shock wave4 kV conforming to IEC 60255-5 4 kV conforming to IEC 60664-1 4 kV conforming to IEC 61000-4-5
dielectric test voltage2 kV, 1 min AC 50 Hz conforming to IEC 60255-5 2 kV, 1 min AC 50 Hz conforming to IEC 60664-1