Opis

on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC

Tehnične lastnosti

Glavno
Serija izdelkaZelio Time
Izdelek ali sestavni delmodular timing relay
Kratko ime napraveRE17R
nominal output current8 A
discrete output typerelay
width17.5 mm
time delay range1...10 min 10...100 h 0.1...1 s 6...60 s 6...60 min 1...10 s 1...10 h
time delay typeAt A
Komplementarno
Višina90 mm
mounting support35 mm DIN rail conforming to EN/IEC 60715
Teža izdelka0.07 kg
Povezave - terminaliscrew terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
control typeselector switch front panel
electrical durability100000 cycles (8 A at 250 V AC maximum) for resistive load
mechanical durability10000000 cycles
Kompatibilnostna kodaRE17
local signallingLED indicator for on steady: relay energised, no timing in progress LED indicator for flashing: timing in progress 80 % ON and 20 % OFF LED indicator for pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L) 5 % ON and 95 % OFF
[Uimp] rated impulse withstand voltage5 kV during 1.2/50 µs
Globina72 mm
tightening torque0.6-1 N.m conforming to IEC 60947-1
[Us] rated supply voltage24...240 V AC 50/60 Hz 24 V DC
contacts materialcadmium free
contacts type and composition1 C/O
breaking capacity2000 VA
housing materialself-extinguishing
on-load factor100 %
OznačevanjeCE
input voltage10 V
repeat accuracy+/- 0.5 % conforming to IEC 61812-1
maximum delay response100 ms
insulation resistance100 MOhm at 500 V DC conforming to IEC 60664-1
mounting positionany position in relation to normal vertical mounting plane
power consumption in VA0-32 VA at 240 V AC
safety reliability dataB10d = 270000 MTTFd = 296.8 years
supply frequency50...60 Hz +/- 5 %
maximum switching current8 A AC/DC
minimum switching current10 mA at 5 V DC
maximum switching voltage250 V AC
maximum power consumption in W0.6 W at 24 V DC
dielectric strength2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
operating rate in Hz10 Hz
setting accuracy of time delay+/- 10 % of full scale at 25 °C conforming to IEC 61812-1
creepage distance4 kV/3 conforming to IEC 60664-1
voltage range0.85...1.1 Us
reset time120 ms on de-energisation typical
voltage drift+/- 0.2 %/V
functionalityon-delay timing
temperature drift+/- 0.05 %/°C
impulse duration100 ms with load in parallel typical 30 ms typical
time delay typeA, At
Okolje
Temperatura okoliškega zraka za delovanje-20-60 °C
IP stopnja zaščiteIP20 (terminal block) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529
Temperatura okoliškega zraka za skladiščenje-30-60 °C
relative humidity93-93 % without condensation conforming to IEC 60068-2-30
Certifikati izdelkovCSA cULus GL
Standardi2006/95/EC 2004/108/EC IEC 61812-1 EN 61000-6-3 EN 61000-6-1 EN 61000-6-4 EN 61000-6-2
Odporno proti udarcu15 gn for 11 ms conforming to IEC 60068-2-27
Odpornost proti vibracijam20 m/s² (f= 10-150 Hz) conforming to IEC 60068-2-6
Elektromagnetna kompatibilnostelectrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2 electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2 susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3 electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4 electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5 conducted RF disturbances: (0.15...80 MHz), level 3, 10 V, conforming to IEC 61000-4-6 voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11 voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11 conducted and radiated emissions: , class B, conforming to EN 55022
immunity to microbreaks20 ms