KT 3X3200AL BOLT ON LENGTH 4M

Tehnične lastnosti

Glavno
Serija izdelkaCanalis
Izdelek ali sestavni delbusbar trunking
product nameKT
Skupina izdelkovCanalis
Aplikacija napravehigh power distribution
Kratko ime napraveKTA
[Ie] rated operational current3200 A at 35 °C
busbar descriptiondistribution length
earth circuitstandard earth
variantstandard version
number of tap-off outlets2
Provided equipmenttrunking unit jointing unit
Materialaluminium
length4000 mm
nominal output current400-1250 A
busbar trunking polarity3L + PE
Združljivost serije/obsegabolt-on tap-off unit from Canalis - KT
Komplementarno
network frequency50/60 Hz
Višina324 mm
mounting supportpendant cantilever arm
Teža izdelka124 kg
[Ui] Nazivna izolacijska trdnost1000 V
mounting modeby hook
colourwhite (RAL 9001)
Širina140 mm
[Ue] rated operational voltage1000 V
standardsIEC 61439-1 IEC 61439-6
contacts materialcopper
[Icw] rated short-time withstand current86 kA
dimension typefix
installation directionhorizontal vertical
THDI0-15 % 3200 A 15-33 % 4000 A
linear resistanceL: R1 35 °C= 0.021 mΩ/m at Inc and 50 Hz L: X1 35 °C= 0.007 mΩ/m at Inc and 50 Hz L: Z1 35 °C= 0.022 mΩ/m at Inc and 50 Hz L - PE: R0 20 °C= 0.303 mΩ/m symmetrical components method L - PE: X0 20 °C= 0.17 mΩ/m symmetrical components method L - PE: Z0 20 °C= 0.347 mΩ/m symmetrical components method L - L: Rb0 20 °C= 0.038 mΩ/m impedance method L - PE: Rb0 20 °C= 0.154 mΩ/m impedance method L - L: Rb1 35 °C= 0.049 mΩ/m at Inc with impedance method L - PE: Rb1 35 °C= 0.197 mΩ/m at Inc with impedance method L - L: Xb 35 °C= 0.01 mΩ/m at Inc and 50 Hz with impedance method L - PE: Xb 35 °C= 0.106 mΩ/m at Inc and 50 Hz with impedance method L: R20 20 °C= 0.017 mΩ/m PE: 20 °C= 0.093 mΩ/m
electrical connectionbolted connection
housing materialpolyester film
neutral positionright
tap-off unit interval2000 mm
linear load31 kg/m
radiated magnetic field2.1 µT
maximum voltage drop <0.0018 V with power factor = 1 at 50 Hz with 1A for 100 m long <0.0019 V with power factor = 0.9 at 50 Hz with 1A for 100 m long <0.0018 V with power factor = 0.8 at 50 Hz with 1A for 100 m long <0.0017 V with power factor = 0.7 at 50 Hz with 1A for 100 m long
[Ipk] rated peak withstand current189 kA
thermal stress limit7396 A².s
Okolje
Temperatura okoliškega zraka za delovanje0-35 °C (100 % of In) 35-40 °C (97 % of In) 40-45 °C (93 % of In) 45-50 °C (90 % of In) 50-55 °C (86 % of In)
IP stopnja zaščiteIP55 conforming to IEC 60529
IK stopnja zaščiteIK08 conforming to IEC 62262