Opis

Micrologic 2.0 X control unit, for Masterpact MTZ circuit breakers, fixed, LI protections

Tehnične lastnosti

Glavno
network typeAC
Izdelek ali sestavni delcontrol unit
Skupina izdelkovMasterpact
Opis polov3P 4P
Aplikacija napraveequipment protection, monitoring and control
Kratko ime napraveMicrologic 2.0 X
trip unit technologyelectronic
trip unit nameMicrologic 2.0 X
trip unit rating3200-3200 A 5000-5000 A 1600-1600 A 630-630 A 1250-1250 A 2500-2500 A 400-400 A 6300-6300 A 800-800 A 1000-1000 A 2000-2000 A 4000-4000 A
protected poles description3P 3d 4P 4d 4P 3d + OSN 4P 3d + N/2 4P 3d
protection typeinstantaneous short-circuit protection conforming to ANSI 50 overload (long time) conforming to ANSI 49
Združljivost serije/obsega Masterpact MTZ1 circuit breaker Masterpact MTZ2 circuit breaker Masterpact MTZ3 circuit breaker
trip unit protection functionsLI
circuit breaker applicationdistribution IEC standard
Komplementarno
network frequency50/60 Hz
mounting modefixed
instantaneous pick-up adjustment range1.5...10 x Ir adjustable in step of 0.5 x Ir with embedded HMI 1.5...10 x Ir adjustable in step of 0.1 x Ir with Ecoreach software or Masterpact MTZ mobile app
long time delay adjustment typeadjustable in step of 0.5 s
instantaneous pick-up adjustment type Iiadjustable
long time pick-up adjustment range0.4...1 x In adjustable in step of 1 A
electromagnetic compatibilityelectrostatic discharge immunity test conforming to IEC 61000-4-2 susceptibility to electromagnetic fields conforming to IEC 61000-4-3 electrical fast transient/burst immunity test conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5 conducted RF disturbances conforming to IEC 61000-4-6 conducted and radiated emissions A conforming to CISPR 22
measurement accuracypower factor: +/- 1 % active energy Ep IN/OUT/tot: +/- 1 % - 10...10 GWh reactive energy Ep IN/OUT/tot: +/- 2 % - 10...10 GVARh apparent energy Es IN/OUT/tot: +/- 1 % - 10...10 GVAh unbalance current: +/- 0.5 % frequency: +/- 0.005 Hz voltage V21, V32, V13, VLLavg: +/- 0.5 % 208...690 x 1.2 V voltage V21, V32, V13, VLNavg: +/- 0.5 % 120...400 x 1.2 V apparent power S, S1, S2, S3, Sdemand: +/- 1 % active power P, P1, P2, P3, Pdemand: +/- 1 % reactive power Q, Q1, Q2, Q3, Qdemand: +/- 2 % current I1, I2, I3, Iavg, Idemand for MTZ1: +/- 0.5 % 40...1600 x 1.2 A current I1, I2, I3, Iavg, Idemand for MTZ2: +/- 0.5 % 40...4000 x 1.2 A current I1, I2, I3, Iavg, Idemand for MTZ3: +/- 0.5 % 80...6300 x 1.2 A
display typeLCD display - 128 x 96 pixels
communication port protocolBluetooth 4.0 LE peer to peer 30 kbit/s NFC peer to peer 28800 bauds conforming to ISO 15963 USB peer to peer 115 kbauds
thermal memoryyes
[tr] long-time delay adjustment range12.5-600 s at 1.5 x Ir 0.5-24 s at 6 x Ir 0.7-16.6 s at 7.2 x Ir
type of measurementpower meter
zone selective interlocking ZSIwith
measurement voltage145.6-145.6 V AC 50/60 Hz per phase 828-828 V AC 50/60 Hz per phase
network and machine diagnosis typesystem (HMI) health state overview: circuit breaker health state standard) contacts state: circuit breaker health state standard) micrologic service life: circuit breaker health state standard) tripping cause indication: circuit breaker tripping cause standard) identification card: diagnostic data standard) configured alarms synthesis: diagnostic data standard) monitored function: diagnostic data standard) operation: diagnostic data standard) micrologic test: test standard) protection test: test standard) selectivity test: test standard) trip context information: crisis management standard) operation: advanced diagnostic standard) breaker service life: circuit breaker health state standard)
metering typecurrent I1, I2, I3, In, Ig: maximum standard) average voltage Vavg standard) active power P, P1, P2, P3 standard) reactive power Q, Q1, Q2, Q3 standard) apparent power S, S1, S2, S3 standard) power factor standard) frequency standard) total current harmonic distortion THD (I): inst, avg, avg min, avg max fundamental voltage standard) total current harmonic distortion THD (I): inst, avg, avg min, avg max RMS voltage standard) voltage V21, V32, V13, V1, V2, V3: instantaneous standard) voltage V21, V32, V13, V1, V2, V3: minimum standard) voltage V21, V32, V13, V1, V2, V3: maximum standard) total voltage harmonic distortion THD (V): inst, avg, avg min, avg max fundamental voltage standard) total voltage harmonic distortion THD (V): inst, avg, avg min, avg max RMS voltage standard) demand current I1, I2, I3, In, Iavg standard) demand power P, Q, S standard)
frequency measurement range40-70 Hz
data recordingalarm logs data logs min/max of instantaneous values event logs time stamping maintenance logs
energy managementmeasurement ,active, reactive and apparent energy (standard) measurement ,electrical network (standard) measurement ,energy (standard)
accuracy classclass 5: total current harmonic distortion THD (I) class 0.5: unbalance voltage class 1: active and reactive energy by pulse counting (+/- W.h, +/- VAR.h) class 2: total voltage harmonic distortion THD (V)
Okolje
StandardiEN/IEC 60255-1 EN/IEC 60947-2 IEC 60092-202 EN/IEC 60947-1