Menu
Vaša košarica

KSA400ED33012 Schneider Electric

KSA400ED33012  Schneider Electric
KSA400ED33012 Schneider Electric

Opis

STRAIGHT DISTRIBUTION LENGTH 3M 400 A

Tehnične lastnosti

Glavno
Serija izdelkaCanalis
Izdelek ali sestavni delbusbar trunking
product nameKS
Skupina izdelkovCanalis
Aplikacija napravemedium power distribution
Kratko ime napraveKSA
[Ie] rated operational current400 A at 35 °C
busbar descriptiondistribution length
number of tap-off outlets12
Materialaluminium
Komplementarno
network frequency50/60 Hz
Teža izdelka19.14 kg
[Ui] Nazivna izolacijska trdnost690 V
mounting modeby screws
[Uimp] rated impulse withstand voltage8 kV
Širina146 mm
Globina54 mm
[Ue] rated operational voltage230...690 V
[Icw] rated short-time withstand current18.8 kA
dimension typefix
THDI33-100 % 250 A 15-33 % 315 A 0-15 % 400 A
linear resistanceR1 0.21 mΩ/m 35 °C at Inc L 50/60 Hz X1 0.14 mΩ/m 35 °C at Inc L 50/60 Hz R0 0.74 mΩ/m 20 °C symmetrical components method L-N 50/60 Hz X0 0.67 mΩ/m 20 °C symmetrical components method L - PE 50/60 Hz Z0 1.11 mΩ/m 20 °C symmetrical components method L - PE 50/60 Hz Rb1 0.57 mΩ/m 35 °C at Inc with impedance method L - L 50/60 Hz Rb1 0.7 mΩ/m 35 °C at Inc with impedance method L-N 50/60 Hz R20 0.15 mΩ/m 20 °C L 50/60 Hz Z0 1 mΩ/m 20 °C symmetrical components method L-N 50/60 Hz Rb0 0.41 mΩ/m 20 °C at Inc with impedance method L - L 50/60 Hz Rb0 0.51 mΩ/m 20 °C at Inc with impedance method L-N 50/60 Hz Rb0 0.55 mΩ/m 20 °C at Inc with impedance method L - PE 50/60 Hz Xb 0.28 mΩ/m 35 °C at Inc and 50 Hz with impedance method L - L 50/60 Hz Xb 0.39 mΩ/m 35 °C at Inc and 50 Hz with impedance method L - PE 50/60 Hz Z1 0.25 mΩ/m 35 °C at Inc L 50/60 Hz 0.19 mΩ/m 20 °C PE 50/60 Hz X0 0.67 mΩ/m 20 °C symmetrical components method L-N 50/60 Hz R0 0.88 mΩ/m 20 °C symmetrical components method L - PE 50/60 Hz Rb1 0.76 mΩ/m 35 °C at Inc with impedance method L - PE 50/60 Hz Xb 0.39 mΩ/m 35 °C at Inc and 50 Hz with impedance method L-N 50/60 Hz
electrical connectionlubricated sliding contact
neutral positionup
radiated magnetic field1 µT
maximum voltage drop <0.021 V with power factor = 0.7 at 50 Hz with 1A for 100 m long <0.018 V with power factor = 1 at 50 Hz with 1A for 100 m long <0.022 V with power factor = 0.9 at 50 Hz with 1A for 100 m long <0.022 V with power factor = 0.8 at 50 Hz with 1A for 100 m long
[Ipk] rated peak withstand current49.2 kA
thermal stress limit354 kA².s
busbar trunking polarity3L + PE
length3-3 m
mounting positionhorizontal
Okolje
StandardiIEC 60439-2 IEC 61439-6