LTMR100MFM Schneider Electric

LTMR100MFM Schneider Electric
Opis
motor controller LTMR TeSys T - 100..240 V AC 100 A for Modbus
Tehnične lastnosti
| Glavno | |
| Izdelek ali sestavni del | motor controller |
| product name | TeSys T |
| Skupina izdelkov | TeSys |
| Aplikacija naprave | equipment monitoring and control |
| Kratko ime naprave | LTMR |
| [Us] Nazivna napajalna npetost | 100...240 V AC 50/60 Hz |
| communication port protocol | Modbus |
| supply voltage limits | 93.5-264 V AC |
| current consumption | 8...62.8 mA |
| bus type | Modbus 2-wire RS 485 interface, addressing 1...247, transmission rate 1.2...19.2 kbit/s, RJ45 with 2 shielded twisted pairs Modbus 2-wire RS 485 interface, addressing 1...247, transmission rate 1.2...19.2 kbit/s, terminal block with 2 shielded twisted pairs |
| measurement current | 5-100 A |
| Komplementarno | |
| Višina | 61 mm |
| Teža izdelka | 0.53 kg |
| Povezave - terminali | control circuit: connector 1 cable(s) 0.25-2.5 mm² (AWG 24...AWG 14) flexible with cable end control circuit: connector 1 cable(s) 0.2-2.5 mm² (AWG 24...AWG 14) flexible without cable end control circuit: connector 1 cable(s) 0.25-2.5 mm² (AWG 24...AWG 14) flexible without cable end control circuit: connector 1 cable(s) 0.2-2.5 mm² (AWG 24...AWG 14) solid without cable end control circuit: connector 2 cable(s) 0.2-1 mm² (AWG 24...AWG 14) flexible with cable end control circuit: connector 2 cable(s) 0.2-1.5 mm² (AWG 24...AWG 14) flexible without cable end control circuit: connector 2 cable(s) 0.5-1.5 mm² (AWG 24...AWG 14) flexible without cable end control circuit: connector 2 cable(s) 0.2-1 mm² (AWG 24...AWG 14) solid without cable end |
| [Ui] Nazivna izolacijska trdnost | 690 V conforming to EN/IEC 60947-1 690 V conforming to CSA C22.2 No 14 690 V conforming to UL 508 |
| Kompatibilnostna koda | LTMR |
| [Uimp] rated impulse withstand voltage | 4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV communication circuit conforming to EN/IEC 60947-4-1 |
| Širina | 91 mm |
| Globina | 122.5 mm |
| tightening torque | control circuit: 0.5-0.6 N.m flat screwdriver 3 mm |
| protection type | load fluctuation earth-leakage protection overload (long time) overload locked rotor thermal protection thermal overload protection power factor variation reverse polarity protection phase failure phase unbalance |
| contacts type and composition | 1 NO + 1 NC fault signal 3 NO |
| connection pitch | 5.08 mm |
| maximum operating rate | 1800 cyc/h |
| input current | 3.1 mA at 100 V 7.5 mA at 240 V |
| overvoltage category | III |
| electromagnetic compatibility | electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 |
| measurement accuracy | 5...15 % earth fault current internal measurement 1 % voltage (100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 temperature 5 % active and reactive power 0,02 current |
| pollution degree | 3 |
| associated fuse rating | 4 A gG for output 0.5 A gG for control circuit |
| web services | web server |
| short-circuit withstand | 100 kA conforming to EN/IEC 60947-4-1 |
| current state 1 guaranteed | logic input: 79...264 V and >= 2 mA for 25 ms |
| current state 0 guaranteed | logic input: 0...40 V and <= 15 mA for 25 ms |
| load current | 5 A at 250 V AC for logic output 5 A at 30 V DC for logic output |
| permissible power | 480 VA (AC-15), Ie = 2 A, 500000 cycles (output) 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output) |
| network and machine diagnosis type | motor control command recording starting current and time trip history information phase fault and earth fault trip counters running hours counter/operating time remaining operating time before overload tripping fault recording trip context information event recording waiting time after overload tripping |
| logic input number | 6 |
| maximum operating frequency | 2 Hz |
| metering type | temperature earth-fault current average current Iavg imbalance current phase current I1, I2, I3 RMS |
| Okolje | |
| Temperatura okoliškega zraka za delovanje | -20-60 °C |
| IP stopnja zaščite | IP20 |
| Temperatura okoliškega zraka za skladiščenje | -40-80 °C |
| Nadmorska višina delovanja | <= 2000 m without derating |
| Certifikati izdelkov | LROS (Lloyds register of shipping) UL ABS ATEX EAC CCC BV RINA DNV C-Tick RMRoS CSA GL NOM KERI |
| Standardi | IACS E10 IEC 60947-4-1 UL 508 EN 60947-4-1 CSA C22.2 No 14 |
| Zaščitna obdelava | 12 x 24 hour cycles conforming to EN/IEC 60068-2-30 48 h conforming to EN/IEC 60070-2-11 TH conforming to EN/IEC 60068 |
| fire resistance | 650 °C conforming to EN/IEC 60695-2-12 960 °C conforming to UL 94 |
| mechanical robustness | vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6 vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6 shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27 |




