XPSMF3502 Schneider

XPSMF3502 Schneider
Opis
Preventa safety PLC compact - 24 I not isolated
Tehnične lastnosti
| Glavno | |
| Serija izdelka | Preventa Safety automation |
| Izdelek ali sestavni del | Preventa safety PLC compact |
| structure type | 10BASE-T/100BASE-TX, Modbus TCP/IP 10BASE-T/100BASE-TX, safe Ethernet |
| safety module name | XPSMF35 |
| safety module application | for numerous machine safety functions and for the protection of personnel |
| safety use category | category 4 conforming to EN 954-1/ISO 13849-1 SIL 3 conforming to IEC 61508 |
| Komplementarno | |
| Višina | 113 mm |
| mounting support | 35 mm symmetrical DIN rail |
| Teža izdelka | 1.2 kg |
| Povezave - terminali | analogue input circuit: captive screw clamp terminals, 2 x 0.5 mm² (AWG 20) flexible with cable end power supply: captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² (AWG 22...AWG 16) flexible with cable end power supply: captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² (AWG 22...AWG 16) flexible without cable end discrete input/output circuit: captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² (AWG 28...AWG 20) solid without cable end discrete input/output circuit: captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² (AWG 28...AWG 18) flexible without cable end power supply: captive screw clamp terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 12) flexible without cable end discrete input/output circuit: captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² (AWG 22) flexible without cable end power supply: captive screw clamp terminals, 2 x 0.25...2 x 1 mm² (AWG 22...AWG 18) flexible without cable end power supply: captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² (AWG 22...AWG 16) flexible with cable end analogue input circuit: captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) flexible without cable end counting inputs: captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) flexible without cable end counting inputs: captive screw clamp terminals, 2 x 0.5 mm² (AWG 20) flexible with cable end analogue input circuit: captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) solid without cable end counting inputs: captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) solid without cable end analogue input circuit: captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² (AWG 22...AWG 20) flexible with cable end counting inputs: captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² (AWG 22...AWG 20) flexible with cable end analogue input circuit: captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² (AWG 22...AWG 16) flexible without cable end counting inputs: captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² (AWG 22...AWG 16) flexible without cable end analogue input circuit: captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² (AWG 28...AWG 20) solid without cable end counting inputs: captive screw clamp terminals, 2 x 0.14...2 x 0.5 mm² (AWG 28...AWG 20) solid without cable end analogue input circuit: captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² (AWG 28...AWG 18) flexible without cable end counting inputs: captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² (AWG 28...AWG 18) flexible without cable end discrete input/output circuit: captive screw clamp terminals, 2 x 0.5 mm² (AWG 20) flexible with cable end power supply: captive screw clamp terminals, 2 x 0.2...1 x 1.5 mm² (AWG 24...AWG 12) solid without cable end analogue input circuit: captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² (AWG 22) flexible without cable end counting inputs: captive screw clamp terminals, 2 x 0.25...2 x 0.34 mm² (AWG 22) flexible without cable end discrete input/output circuit: captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) flexible without cable end discrete input/output circuit: captive screw clamp terminals, 1 x 0.14...1 x 1.5 mm² (AWG 28...AWG 16) solid without cable end power supply: captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible without cable end power supply: captive screw clamp terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) solid without cable end discrete input/output circuit: captive screw clamp terminals, 1 x 0.25...1 x 0.5 mm² (AWG 22...AWG 20) flexible with cable end discrete input/output circuit: captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² (AWG 22...AWG 16) flexible without cable end |
| wire stripping length | 9 mm |
| Širina | 253 mm |
| Globina | 66.5 mm |
| tightening torque | 0.22-0.25 N.m |
| [Us] rated supply voltage | 24 V DC - 15...20 % |
| Poraba toka | 9 A at 24 V DC on power supply |
| protection type | internal fuse |
| voltage state 0 guaranteed | <= 5 V for discrete input |
| voltage state 1 guaranteed | 24...30 V for discrete input |
| number of terminal blocks | 1 for counting inputs 1 for power supply 2 for discrete output 4 for analogue input circuit 5 for discrete input |
| response time | depending on size of application |
| analogue output type | not isolated |
| analogue input number | 8 |
| discrete output number | 8 |
| communication port protocol | Modbus TCP/IP with 4 RJ45 port(s), transmission rate: 100 Mbps, 10 Mbps, medium: dual twisted pair cable, category 5D or better safe Ethernet with 4 RJ45 port(s), transmission rate: 100 Mbps, 10 Mbps, medium: dual twisted pair cable, category 5D or better Modbus RTU with 1 SUB-D 9-pin female port(s), RS485, medium: shielded dual twisted pair cable Profibus with 1 SUB-D 9-pin female port(s), RS485, medium: shielded dual twisted pair cable |
| method of access | slave Modbus slave Modbus TCP/IP slave Profibus |
| discrete input number | 24 not isolated discrete input(s) |
| number of addresses | 122-122 for Modbus |
| exchange mode | half duplex, full duplex, autonegotiation Modbus TCP/IP half duplex, full duplex, autonegotiation safe Ethernet |
| discrete output current | 1 A at 60 °C (channels 4 and 8) 2 A at 50 °C (channels 4 and 8) 0.5 A at 60 °C (channels 1 to 3 and 5 to 7) <= 7 mA (all channels) |
| minimum load | 2 mA per discrete output |
| maximum leakage current | 1 mA, at 2 V at state 0 for discrete output |
| web server | class A10, Modbus TCP/IP |
| web services | Modbus identification request, Modbus TCP/IP Modbus TCP/IP messaging (reading/writing of data words), Modbus TCP/IP Modbus TCP/IP server, Modbus TCP/IP Standard 502, Modbus TCP/IP |
| discrete input voltage | 20 V |
| discrete input current | 100 mA |
| current state 1 guaranteed | 3.5...4.5 mA (discrete input) |
| output voltage tolerance | +/- 2 % |
| discrete output voltage | 24 V DC |
| current state 0 guaranteed | 1...1.5 mA (discrete input) |
| input protection type | protected against short-circuit protected against short-circuit to earth |
| memory description | user logic 250 kB application user logic 250 kB data |
| dV/dt | 1 V/µs counting inputs |
| input current limits | 0.4-23 mA 500 Ohm analogue input circuit |
| input voltage limits | 0.1...11.5 V analogue input circuit |
| clock | with, supplied by backup capacitor for 1 week following loss of supply |
| analogue input range | 0...20 mA with 500 Ohm shunt 0...10 V |
| overload protection | shutdown of outputs concerned with cyclic reconnection |
| operating distance | <= 500 m (between station) shielded dual twisted pair cable counting inputs <= 100 m (between station) discrete input <= 100 m (between station) discrete output <= 300 m (between station) analogue input circuit |
| analogue input resolution | 12 bits |
| counting frequency | 100 kHz |
| counting input number | 2 |
| counter inputs resolution | 24 bits |
| counting input type | non isolated |
| input overvoltage protection | 500-500 V for discrete input conforming to IEC 61000-4-5 -4-15 V for analogue input circuit |
| no load current | 0.75 A |
| function of module | closed circuit scanning of input channels for analogue input circuit measuring 0 to 20 mA currents using shunt for analogue input circuit monitoring safety actuators for discrete output monitoring safety detection for discrete input monitoring safety dialogue for discrete input monitoring safety dialogue for discrete output single-pole measuring of 0 to 10 V voltages for analogue input circuit |
| operating threshold | 0...0.05 V, 5 V low for counting inputs 13...33 V, 24 V high for counting inputs -3...5 V, 24 V low for counting inputs 4...6 V, 5 V high for counting inputs |
| concept | Transparent Ready, Modbus TCP/IP |
| external resistance | 250 Ohm for analogue input circuit 500 Ohm for analogue input circuit |
| maximum internal input resistance | 500 MOhm for signal source for analogue input circuit 1 kOhm for analogue input circuit 3.7 Ohm for counting inputs |
| safety accuracy | +/- 2 % for analogue input circuit |
| Okolje | |
| Temperatura okoliškega zraka za delovanje | 0-60 °C conforming to EN 61131-2 |
| IP stopnja zaščite | IP20 (enclosure) |
| Stopnja onesnaženosti | 2 |
| Temperatura okoliškega zraka za skladiščenje | -40-85 °C conforming to EN 61131-2 |
| relative humidity | 95-95 % supply not connected |
| Nadmorska višina delovanja | < 2000 m |
| Odpornost na elektromagnetna polja | 10 V/m 26-1000 MHz conforming to EN/IEC 61000-4-3 |
| Standardi | IEC 61131 DIN V 19250 EN 50156 pending DIN V 0801 |
| Odporno proti udarcu | 15 gn for 11 ms conforming to EN 61131-2 |
| Odpornost proti vibracijam | 1 gn conforming to EN 61131-2 (f = 10-150 Hz) |
| Odpornost na elektrostatično razelektritev | 4 kV contact conforming to EN/IEC 61000-4-2 8 kV on air conforming to EN/IEC 61000-4-2 |
| electrical shock protection class | class II conforming to EN/IEC 61131-2 |
| Elektromagnetna kompatibilnost | EN/IEC 61131-2 |
| immunity to microbreaks | 10 ms |