XPSATR1153P Schneider

XPSATR1153P  Schneider
XPSATR1153P Schneider

Opis

module XPSATR - Emergency stop and protective guard - 24V DC, time delay 3s

Tehnične lastnosti

Glavno
Serija izdelkaPreventa Safety automation
Izdelek ali sestavni delPreventa safety module
[Us] Nazivna napajalna npetost24 V DC - 15...10 %
output typerelay instantaneous opening, 3 NO circuit(s), volt-free relay time delay opening, 3 NO circuit(s), volt-free
connections - terminalscaptive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid or flexible without cable end captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid or flexible without cable end captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with bezel
type of startautomatic manual
safety module nameXPSATR
safety module applicationfor emergency stop and protective guard applications
function of moduleemergency stop monitoring 2-channel wiring emergency stop monitoring 1-channel wiring protective guard monitoring
number of additional circuits1 NC
safety reliability dataDC > 99 % conforming to EN/ISO 13849-1 MTTFd = 85 years conforming to EN/ISO 13849-1 PFHd = 2E-9 1/h conforming to EN/IEC 62061
safety levelcan reach PL e/category 4 instantaneous safety outputs conforming to EN/ISO 13849-1 can reach SILCL 3 time delay safety outputs conforming to EN/IEC 62061
Komplementarno
mounting support35 mm symmetrical DIN rail
Teža izdelka0.33 kg
[Ui] Nazivna izolacijska trdnost300 V
local signalling5 LEDs
[Uimp] rated impulse withstand voltage4 kV overvoltage category III conforming to EN/IEC 60947-5-1, DIN VDE 0110 parts 1 & 2
[Ith] conventional free air thermal current8 A
[Uc] control circuit voltage24 V DC
breaking capacity3 A at 24 V (DC-13) for relay output
time delay range0.1...3 s
maximum power consumption in W2.8 W DC
associated fuse rating6 A gG for instantaneous and time delay outputs conforming to EN/IEC 60947-5-1, DIN VDE 0660 part 200
input protection typeinternal, electronic
output thermal current6 A for instantaneous and time delay outputs
minimum output voltage17 V for relay output
minimum output current10 mA for relay output
maximum response time on input open20 ms
synchronisation time between inputs1 s
Okolje
Temperatura okoliškega zraka za delovanje-25-55 °C
IP stopnja zaščiteIP20 (terminals) conforming to EN/IEC 60529 IP40 (enclosure) conforming to EN/IEC 60529
Temperatura okoliškega zraka za skladiščenje-25-75 °C
Certifikati izdelkovTÜV CSA UL
StandardiEN 62061 EN/IEC 61496-1 EN/ISO 13849-1 EN 60204-1 EN 50156-1 EN/IEC 60947-5-1