photo-electric sensor - XUL - reflex - Sn 6m - 24..240VAC/DC - 1/2"

Tehnične lastnosti

Glavno
Serija izdelkaOsiSense XU
Materialplastic
sensor designcompact
series namegeneral purpose single mode
electrical connection1 male connector 1/2"20 UNF, 3 pins
product specific application-
discrete output function1 NC
type of output signaldiscrete
sensor nameXUL
wiring technique2-wire
[Sn] nominal sensing distance6-6 m reflex need reflector XUZC80
emissioninfrared reflex
sensing range> 5...15 m
detection systemreflex
supply circuit typeAC/DC
electronic sensor typephoto-electric sensor
Komplementarno
Višina70 mm
Teža izdelka0.135 kg
Širina18 mm
Globina35 mm
[Us] rated supply voltage24...240 V AC/DC
Omejitve napajalne napetosti20-264 V AC/DC
maximum voltage drop <10 V (closed state)(I = 5 mA) <3 V (closed state)(I = 0.1...0.5 A) <5.5 V (closed state)(I = 10 mA)
cable outer diameter6 mm
enclosure materialABS/PC
maximum delay response20 ms
maximum residual current1.5 mA open state AC/DC
switching frequency<= 20 Hz
maximum delay recovery20 ms
maximum delay first up300 ms
wire insulation materialPVC
cable composition2 x 0.34 mm²
status LED1 LED for output state
lens materialPMMA
setting-upwithout sensitivity adjustment
maximum sensing distance9 m with reflector Ø 80 mm
switching capacity in mA<= 3000 mA (inrush mode, to be used with 0.63 A quick-blow fuse in series with the load) >= 5 mA (sealed mode, to be used with 0.63 A quick-blow fuse in series with the load)
output typesolid state
add on outputwithout
kit compositionsensor bracket XULZ41
output function governancelight
Okolje
Temperatura okoliškega zraka za delovanje-25-60 °C
IP stopnja zaščiteIP65 conforming to IEC 60529 IP651 conforming to NF C 20-010
Temperatura okoliškega zraka za skladiščenje-40-80 °C
Certifikati izdelkovCE
Odporno proti udarcu20 gn (duration = 11 ms) conforming to IEC 60068-2-27
Odpornost proti vibracijam7 gn, amplitude = +/- 2 mm (f = 10-55 Hz) conforming to IEC 60068-2-6