BMXP342020 Schneider Electric

BMXP342020  Schneider Electric
BMXP342020 Schneider Electric

Opis

processor module M340 - max 1024 discrete + 256 analog I/O - Modbus - Ethernet

Tehnične lastnosti

Glavno
Serija izdelkaModicon M340 automation platform
Izdelek ali sestavni delprocessor module
conceptTransparent Ready CANopen
number of racks4
analogue I/O processor capacity256 I/O multi-rack configuration 66 I/O single-rack configuration
number of slots11
monitoringdiagnostic counters Modbus event counters Modbus
number of application specific channel36
discrete I/O processor capacity1024 I/O multi-rack configuration 704 I/O single-rack configuration
Komplementarno
Teža izdelka0.205 kg
Poraba toka95 mA at 24 V DC
OznačevanjeCE
status LED1 LED (green)activity on Ethernet network (ETH ACT): 1 LED (green)processor running (RUN): 1 LED (green)status of Ethernet network (ETH STS): 1 LED (red)data rate (ETH 100): 1 LED (red)I/O module fault (I/O): 1 LED (red)memory card fault (CARD ERR): 1 LED (red)processor or system fault (ERR): 1 LED (yellow)activity on Modbus (SER COM):
number of addresses0-248 for character mode 0-248 for Modbus
supplyinternal power supply via rack
communication servicebandwidth management, Ethernet TCP/IP Data Editor, Ethernet TCP/IP Modbus TCP messaging, Ethernet TCP/IP Rack Viewer, Ethernet TCP/IP SNMP network administrator, Ethernet TCP/IP
integrated connection typenon isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS232C, transmission mode: 2 twisted shielded pairs at 0.3...19.2 kbit/s full duplex non isolated serial link RJ45 character mode, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3...19.2 kbit/s half duplex non isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS232C, transmission mode: 1 twisted shielded pair at 0.3...19.2 kbit/s half duplex non isolated serial link RJ45, master/slave Modbus, RTU/ASCII, transmission mode: asynchronous in baseband, RS485, transmission mode: 1 twisted shielded pair at 0.3...19.2 kbit/s half duplex USB port at 12 Mbit/s Ethernet TCP/IP RJ45, transmission mode: 1 twisted pair at 10/100 Mbit/s
port Ethernet10BASE-T/100BASE-TX
number of devices2 point-to-point character mode 2 point-to-point Modbus
application structure1 cyclic/periodic master task 1 periodic fast task no auxiliary task 64 event tasks
maximum size of object areas256 kB unlocated internal data 32634 %Mi located internal bits
system overhead0.13 ms for fast task 0.7 ms for master task
execution time per instruction0.12 µs Boolean 0.17 µs double-length words 0.25 µs single-length words 1.16 µs floating points
memory descriptionsupplied memory card (BMXRMS008MP) backup of programs, constants, symbols and data internal RAM 4096 kB internal RAM 256 kB data internal RAM 3584 kB program constants and symbols supplied memory card (BMXRMS008MP) activation of standard web server, class B10
number of devices per segment0-32 (character mode) 0-32 (Modbus)
communication module processor capacity2 Ethernet communication module 4 AS-Interface module
requests1 K data bytes per request character mode 252 data bytes per RTU request Modbus 504 data bytes per ASCII request Modbus
default size of object areas1024 %MWi internal words located internal data 256 %KWi constant words located internal data 512 %Mi located internal bits
maximum tap links length <15 m serial link non isolated character mode segment <15 m serial link non isolated Modbus segment <40 m serial link isolated character mode segment <40 m serial link isolated Modbus segment
control parameterone CRC on each frame (RTU) Modbus one LRC on each frame (ASCII) character mode one LRC on each frame (ASCII) Modbus
number of instructions per ms6.4 Kinst/ms 65 % Boolean + 35 % fixed arithmetic 8.1 Kinst/ms 100 % Boolean
bus length0-10 m serial link non isolated character mode segment 0-10 m serial link non isolated Modbus segment 0-1000 m serial link isolated character mode segment 0-1000 m serial link isolated Modbus segment 0-15 m character mode point-to-point 0-15 m Modbus point-to-point
control channelsprogrammable loops
Okolje
Temperatura okoliškega zraka za delovanje0-60 °C
IP stopnja zaščiteIP20
relative humidity10-95 % without condensation
StandardiEN 61131-2 EN 61000-6-4 EN 61000-6-2 EN 61010-2-201
Zaščitna obdelavaTC
directives2014/35/EU - low voltage directive 2014/30/EU - electromagnetic compatibility 2012/19/EU - WEEE directive