Control unit, TeSys U, 3-12A, 3P motor magnetic protection, coil 48-72V AC/DC

Tehnične lastnosti

Glavno
Serija izdelkaTeSys U
Izdelek ali sestavni delmagnetic control unit
product nameTeSys U
utilisation categoryAC-41 AC-43 AC-44
Skupina izdelkovTeSys
Aplikacija napravemotor control motor protection
Kratko ime napraveLUCL
network frequency40...60 Hz
[Uc] Krmilna napetost48 V AC 48...72 V DC
Združljivost izdelkovpower base LUB12 power base LUB32 power base LUB38 power base LUB120 power base LUB320 power base LUB380 reversing contactor breaker LU2B12ES reversing contactor breaker LU2B32ES
product specific applicationprotection of variable speed drive or soft startsoft stop unit
[Ue] rated operational voltage690 V AC
motor power kW5.5 kW at 400...440 V AC 50/60 Hz 5.5 kW at 500 V AC 50/60 Hz 9 kW at 690 V AC 50/60 Hz
load type3-phase motor - cooling: self-cooled
thermal protection adjustment range3-12 A
function availableshort-circuit protection manual reset
tripping threshold14.2 x Ir +/- 20 %
Komplementarno
Višina66 mm
Teža izdelka0.135 kg
[Ui] Nazivna izolacijska trdnost690 V conforming to IEC 60947-6-2 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1
Kompatibilnostna kodaLUCL
Širina45 mm
Globina60 mm
product certificationsCE UL CSA CCC EAC ASEFA ATEX Marine
standardsEN 60947-6-2 IEC 60947-6-2 UL 60947-4-1, with phase barrier CSA C22.2 No 60947-4-1, with phase barrier
Način pritrjevanjaplug-in (front face)
Omejitve napetosti regulacijskega vezja38.5...72 V for AC circuit 48 V in operation 38.5...93 V for DC circuit 48...72 V in operation 29 V for AC circuit 48 V drop-out 29 V for DC circuit 48...72 V drop-out
heat dissipation2-2 W for control circuit with LUB12 3-3 W for control circuit with LUB32 3-3 W for control circuit with LUB38
operating time35 ms opening with LUB12 for control circuit 35 ms opening with LUB32 for control circuit 35 ms opening with LUB38 for control circuit 60 ms closing with LUB12 for control circuit 60 ms closing with LUB32 for control circuit 60 ms closing with LUB38 for control circuit
typical current consumption280 mA at 48 V AC I maximum while closing with LUB12 280 mA at 48 V AC I maximum while closing with LUB32 280 mA at 48 V AC I maximum while closing with LUB38 280 mA at 48...72 V DC I maximum while closing with LUB12 280 mA at 48...72 V DC I maximum while closing with LUB32 280 mA at 48...72 V DC I maximum while closing with LUB38 35 mA at 48 V AC I rms sealed with LUB12 45 mA at 48 V AC I rms sealed with LUB32 45 mA at 48 V AC I rms sealed with LUB38 35 mA at 48...72 V DC I rms sealed with LUB12 45 mA at 48...72 V DC I rms sealed with LUB32 45 mA at 48...72 V DC I rms sealed with LUB38
safe separation of circuit400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1
Okolje
Temperatura okoliškega zraka za delovanje-25-70 °C
IP stopnja zaščiteIP20 front panel and wired terminals conforming to IEC 60947-1 IP20 other faces conforming to IEC 60947-1 IP40 front panel outside connection zone conforming to IEC 60947-1
Temperatura okoliškega zraka za skladiščenje-40-85 °C
Nadmorska višina delovanja2000 m
Odporno proti udarcu10 gn power poles open conforming to IEC 60068-2-27 15 gn power poles closed conforming to IEC 60068-2-27
Odpornost proti vibracijam2 gn, 5-300 Hz, power poles open conforming to IEC 60068-2-6 4 gn, 5-300 Hz, power poles closed conforming to IEC 60068-2-6
Odpornost na elektrostatično razelektritev8 kV level 3 in open air conforming to IEC 61000-4-2 8 kV level 4 on contact conforming to IEC 61000-4-2
Zaščitna obdelavaTH conforming to IEC 60068
Odpornost proti hitrim prehodnim pojavom2 kV class 3 serial link conforming to IEC 61000-4-4 4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
fire resistance960 °C parts supporting live components conforming to IEC 60695-2-12 650 °C conforming to IEC 60695-2-12
resistance to radiated fields10 V/m 3 conforming to IEC 61000-4-3
non-dissipating shock wave1 kV serial mode conforming to IEC 60947-6-2 2 kV common mode conforming to IEC 60947-6-2
immunity to microbreaks3 ms
immunity to voltage dips70 % / 500 ms conforming to IEC 61000-4-11
immunity to radioelectric fields10 V conforming to IEC 61000-4-6