Motor circuit breaker, TeSys GV3, 3P, 23-32 A, thermal magnetic, EverLink terminals

Tehnične lastnosti

Glavno
Serija izdelkaTeSys GV3
Izdelek ali sestavni delcircuit breaker
product nameTeSys GV3
Skupina izdelkovTeSys
Aplikacija napravemotor
Kratko ime napraveGV3P
trip unit technologythermal-magnetic
Komplementarno
network frequency50/60 Hz conforming to IEC 60947-4-1
Višina132 mm
Teža izdelka0.96 kg
Povezave - terminaliEverLink BTR screw connectors 2 cable(s) 1-25 mm² solid EverLink BTR screw connectors 2 cable(s) 1-25 mm² flexible without cable end EverLink BTR screw connectors 2 cable(s) 1-25 mm² flexible with cable end
control typerotary knob
[Ui] Nazivna izolacijska trdnost690 V AC 50/60 Hz conforming to IEC 60947-2
electrical durability50000 cycles for AC-3 at 440 V In
mechanical durability50000 cycles
Kompatibilnostna kodaGV3P
Širina55 mm
Globina136 mm
tightening torque5 N.m on EverLink BTR screw connectors for cable 25-25 mm² 8 N.m on EverLink BTR screw connectors for cable 35-35 mm²
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
magnetic tripping current448-448 A
[In] rated current32 A
[Ith] conventional free air thermal current32 A conforming to IEC 60947-4-1
operating positionany position
breaking capacity100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
maximum operating rate25 cyc/h
Način pritrjevanja35 mm symmetrical DIN rail: clipped panel: screwed (with 3 x M4 screws)
poles description3P
power dissipation per pole8 W
phase failure sensitivityyes conforming to IEC 60947-4-1
rated dutycontinuous conforming to IEC 60947-4-1
network typeAC
motor power kW15-15 kW at 400/415 V AC 50/60 Hz 18.5-18.5 kW at 500 V AC 50/60 Hz 22-22 kW at 690 V AC 50/60 Hz
utilisation categoryAC-3 conforming to IEC 60947-4-1 category A conforming to IEC 60947-2
[Ics] rated service short-circuit breaking capacity100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolationyes conforming to IEC 60947-1
trip unit rating23-32 A
direct connectorwithout
Okolje
Temperatura okoliškega zraka za delovanje-20-60 °C
IP stopnja zaščiteIP20 conforming to IEC 60529
Temperatura okoliškega zraka za skladiščenje-40-80 °C
Nadmorska višina delovanja3000 m
IK stopnja zaščiteIK09
Certifikati izdelkovIECEE CB Scheme UL CSA CCC EAC ATEX BV LROS (Lloyds register of shipping) DNV-GL ABS
StandardiEN/IEC 60947-2 EN/IEC 60947-4-1 CSA C22.2 No 60947-4-1 UL 60947-4-1
Zaščitna obdelavaTH
fire resistance960 °C conforming to IEC 60695-2-1