Menu
Vaša košarica

GV2RT08 Schneider Electric

GV2RT08  Schneider Electric
GV2RT08 Schneider Electric

Opis

Motor circuit breaker, TeSys GV2, 3P, 2.5-4 A, thermal magnetic, screw clamp terminals

Tehnične lastnosti

Glavno
Serija izdelkaTeSys GV2
Izdelek ali sestavni delcircuit breaker
product nameTeSys GV2
Skupina izdelkovTeSys
Aplikacija napravetransformer motor
Kratko ime napraveGV2RT
trip unit technologythermal-magnetic
Komplementarno
network frequency50/60 Hz conforming to IEC 60947-4-1
Višina89 mm
Povezave - terminaliscrew clamp terminals 2 cable(s) 1-6 mm² solid screw clamp terminals 2 cable(s) 1.5-6 mm² flexible without cable end screw clamp terminals 2 cable(s) 1-4 mm² flexible with cable end
control typetoggle
[Ui] Nazivna izolacijska trdnost690 V AC 50/60 Hz conforming to IEC 60947-2
electrical durability100000 cycles for AC-3 at 440 V
mechanical durability100000 cycles
Kompatibilnostna kodaGV2RT
Širina45 mm
Globina78.5 mm
tightening torque1.7 N.m on screw clamp terminals
[Ue] rated operational voltage690 V AC 50/60 Hz conforming to IEC 60947-2
magnetic tripping current78-78 A
[In] rated current4 A
[Ith] conventional free air thermal current4 A conforming to IEC 60947-4-1
operating positionany position
breaking capacity100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2
maximum operating rate25 cyc/h
Način pritrjevanja35 mm symmetrical DIN rail: clipped panel: screwed (with adaptor plate)
poles description3P
power dissipation per pole2.5 W
rated dutycontinuous conforming to IEC 60947-4-1
network typeAC
motor power kW0.55-0.55 kW at 220/230 V AC 50/60 Hz motor protection high peak current 0.75-0.75 kW at 220/230 V AC 50/60 Hz motor protection high peak current 1.1-1.1 kW at 400/415 V AC 50/60 Hz motor protection high peak current 1.5-1.5 kW at 400/415 V AC 50/60 Hz motor protection high peak current 1.5-1.5 kW at 440 V AC 50/60 Hz motor protection high peak current 1.5-1.5 kW at 500 V AC 50/60 Hz motor protection high peak current 2.2-2.2 kW at 500 V AC 50/60 Hz motor protection high peak current 2.2-2.2 kW at 690 V AC 50/60 Hz motor protection high peak current 3-3 kW at 690 V AC 50/60 Hz motor protection high peak current 1-1 kW at 230/240 V AC 50/60 Hz transformer protection 1.6-1.6 kW at 400/415 V AC 50/60 Hz transformer protection 2-2 kW at 400/415 V AC 50/60 Hz transformer protection 1.6-1.6 kW at 440 V AC 50/60 Hz transformer protection 2-2 kW at 440 V AC 50/60 Hz transformer protection 2-2 kW at 500 V AC 50/60 Hz transformer protection 2.5-2.5 kW at 500 V AC 50/60 Hz transformer protection 2.5-2.5 kW at 690 V AC 50/60 Hz transformer protection
utilisation categoryAC-3 conforming to IEC 60947-4-1 category A conforming to IEC 60947-2
suitability for isolationyes conforming to IEC 60947-1
trip unit rating2.5-4 A
direct connectorwithout
Okolje
Temperatura okoliškega zraka za delovanje-20-60 °C
IP stopnja zaščiteIP20 conforming to IEC 60529
Temperatura okoliškega zraka za skladiščenje-40-80 °C
Nadmorska višina delovanja2000 m
IK stopnja zaščiteIK04
Certifikati izdelkovIECEE CB Scheme UL CSA CCC EAC BV LROS (Lloyds register of shipping)
StandardiEN/IEC 60947-2 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
Zaščitna obdelavaTH
fire resistance960 °C conforming to IEC 60695-2-1