Opis

TeSys D control relay - 3 NO + 2 NC - = 690 V - 125 V DC standard coil

Tehnične lastnosti

Glavno
Serija izdelkaTeSys D control relay
Izdelek ali sestavni delcontrol relay
product nameTeSys CAD
Skupina izdelkovTeSys
Kratko ime napraveCAD
contactor applicationcontrol circuit
Komplementarno
Višina77 mm
mounting supportrail plate
Teža izdelka0.58 kg
Povezave - terminaliscrew clamp terminals 1 cable(s) 1-4 mm²flexible without cable end screw clamp terminals 2 cable(s) 1-4 mm²flexible without cable end screw clamp terminals 1 cable(s) 1-4 mm²flexible with cable end screw clamp terminals 2 cable(s) 1-2.5 mm²flexible with cable end screw clamp terminals 1 cable(s) 1-4 mm²solid without cable end screw clamp terminals 2 cable(s) 1-4 mm²solid without cable end
[Ui] Nazivna izolacijska trdnost600 V UL certified 600 V CSA certified 690 V conforming to IEC 60947-5-1
mechanical durability30 Mcycles
Kompatibilnostna kodaCAD
[Uimp] rated impulse withstand voltage6 kV conforming to IEC 60947
Širina45 mm
Globina93 mm
tightening torque1.2 N.m - on screw clamp terminals - with screwdriver Philips No 2 1.2 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
[Ue] rated operational voltage<= 690 V AC 25...400 Hz
[Ith] conventional free air thermal current10 A (at 60 °C)
[Uc] control circuit voltage125 V DC
[Icw] rated short-time withstand current100 A - 1 s 120 A - 500 ms 140 A - 100 ms
maximum operating rate180 cyc/mn
insulation resistance> 10 MOhm
minimum switching current5 mA
Omejitve napetosti regulacijskega vezjaoperational: 0.7...1.25 Uc drop-out: 0.1...0.25 Uc
non-overlap time1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact
Poraba energije pri zadrževanju v W5.4-5.4 W at 20 °C
time constant28 ms
minimum switching voltage17 V
Vklopna moč v W5.4-5.4 W (at 20 °C)
associated fuse rating10 A gG conforming to IEC 60947-5-1
operating time53...72 ms coil energisation and NO closing 16...24 ms coil de-energisation and NO opening 47...63 ms coil energisation and NC opening 15...25 ms coil de-energisation and NC closing
utilisation categoryDC-13 AC-14 AC-15
mechanical robustnessshocks control relay open: 10 Gn for 11 ms conforming to IEC 60068-2-27 shocks control relay closed: 15 Gn for 11 ms conforming to IEC 60068-2-27 vibrations control relay open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 vibrations control relay closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6
control circuit typeDC standard
Irms rated making capacity140 A AC conforming to IEC 60947-5-1 250 A DC conforming to IEC 60947-5-1
pole contact composition3 NO + 2 NC
Okolje
Temperatura okoliškega zraka za delovanje-40-70 °C
IP stopnja zaščiteIP2x front face conforming to VDE 0106
Temperatura okoliškega zraka za skladiščenje-60-80 °C
Nadmorska višina delovanja3000 m without
Certifikati izdelkovUL CSA
StandardiBS 4794 EN 60947-5 IEC 60947-5-1 NF C 63-140 VDE 0660
Zaščitna obdelavaTH conforming to IEC 60068