Opis

5”7 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Tehnične lastnosti

Glavno
Serija izdelkaMagelis SCU
Izdelek ali sestavni delsmall touch HMI controller
Predstavitev napravecomplete product
display type with backlit LED colour TFT LCD
display size5.7 inch
touch panelanalogue
Komplementarno
Višina129.4 mm
Teža izdelka0.803 kg
local signallingno indicator
Širina163 mm
Globina76.22 mm
[Us] rated supply voltage24 V (20.4-28.8 V)DC
connection pitch3.5 mm
enclosure materialPC/PBT and PAA
insulation resistance> 10 MOhm between the I/O and internal logic > 10 MOhm between power supply and earth
power consumption in W24 W
inrush current30 A
Način pritrjevanjaby 1 nut - diameter: Ø 22 mm, mounting on: 1...6 mm thick panel
electromagnetic compatibilityelectrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to IEC 61000-4-2 surge immunity test - test level: 2 kV (power supply (common mode)) conforming to IEC 61000-4-5 surge immunity test - test level: 1 kV (power supply (differential mode)) conforming to IEC 61000-4-5 surge immunity test - test level: 1 kV common mode (digital I/O) conforming to IEC 61000-4-5 surge immunity test - test level: 0.5 kV differential mode (digital I/O) conforming to IEC 61000-4-5 conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to IEC 61000-4-6 conducted emission - test level: 150 kHz...30 MHz conforming to EN 55011 radiated emission - test level: 30 MHz...1 GHz conforming to EN 55011 electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to IEC 61000-4-2 susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz...3 GHz) conforming to IEC 61000-4-3 electrical fast transient/burst immunity test - test level: 2 kV (power lines) conforming to IEC 61000-4-4 electrical fast transient/burst immunity test - test level: 1 kV (between analogue I/O and operating voltage) conforming to IEC 61000-4-4 electrical fast transient/burst immunity test - test level: 2 kV (relay wires) conforming to IEC 61000-4-4 electrical fast transient/burst immunity test - test level: 1 kV (Ethernet line) conforming to IEC 61000-4-4 electrical fast transient/burst immunity test - test level: 1 kV (COM line) conforming to IEC 61000-4-4 electrical fast transient/burst immunity test - test level: 1 kV (CAN line) conforming to IEC 61000-4-4
analogue input number2 for analog input 2 for RTDs
discrete output number2 fast output (normal mode), output logic: source 6 digital output, output logic: source
analogue output number2 resistive load for 12 bits + sign
discrete input number2 for fast input (normal mode) conforming to IEC 61131-2 Type 1 6 for digital input conforming to IEC 61131-2 Type 1
analogue input typeRTD at - 200...600 °C - resolution: 16 bits temperature probe: Pt 100/Pt 1000 RTD at - 200...1300 °C - resolution: 16 bits (thermocouple N) RTD at - 50...200 °C - resolution: 16 bits temperature probe: Ni 100/Ni 1000 RTD at - 200...760 °C - resolution: 16 bits (thermocouple J) RTD at - 240...1370 °C - resolution: 16 bits (thermocouple K) RTD at 0...1600 °C - resolution: 16 bits (thermocouple R) RTD at 200...1800 °C - resolution: 16 bits (thermocouple B) RTD at 0...1600 °C - resolution: 16 bits (thermocouple S) RTD at - 200...400 °C - resolution: 16 bits (thermocouple T) RTD at - 200...900 °C - resolution: 16 bits (thermocouple E)
supplyexternal source
discrete output current2 A 4 A), response time 5 ms with opening contact for digital output 2 A 4 A), response time 2 ms with closing contact for digital output 300 mA, response time 2 ms for fast output (normal mode) 50 mA, response time 2 ms for fast output (PWM or PTO mode)
integrated connection type1 serial link - RJ45 - RS232/RS485 (rate: <= 115.2 kbits/s) 1 Ethernet TCP/IP - RJ45 1 USB 2.0 type mini B 1 USB 2.0 type A CANopen master bus - SUB-D 9
shock resistance147 m/s² for 11 ms (on DIN rail) conforming to IEC 60068-2-27 294 m/s² for 6 ms (on panel mounting) conforming to IEC 60068-2-27
maximum input frequency100 kHz for fast input (encoder mode) - control type A/B 100 kHz for fast input - control type single phase 100 kHz for fast input - control type pulse/direction
number of pageslimited by internal memory capacity
brightness16 levels via touch panel
backlight lifespan50000 hours with 65000 colours
realtime clockbuilt-in
downloadable protocolsModbus Modbus TCP/IP CANopen
character fontChinese (simplified Chinese) Japanese (ANK, Kanji) ASCII Korean Taiwanese (traditional Chinese)
vibration resistance+/- 3.5 mm (f = 5-9 Hz) conforming to IEC 60068-2-6 1 gn (f = 9-150 Hz) conforming to IEC 60068-2-6
discrete input voltage24 V DC, discrete input logic: sink or source (positive/negative)
discrete input current7.83 mA for fast input 5 mA for digital
discrete output voltage24 V DC (voltage limit: 19.2...28.8 V) with transistor discrete output(s) 24 V DC (voltage limit: 5...30 V) with relay discrete output(s) 220 V AC (voltage limit: 100...250 V) with relay discrete output(s)
maximum output frequency100 kHz for fast output (PTO mode) 1 kHz for fast output (PWM mode)
memory descriptionflash NAND, 128 MB internal data storage FRAM, 128 kB application run DRAM, 128 MB
immunity to microbreaks10 ms
input impedance4.7 kOhm 2.81 kOhm
analogue input range0...20 mA/4...20 mA - resolution: 12 bits, input impedance: 250 Ohm (tolerance: +/- 1 %) -10...+10 V or 0...10 V - resolution: 12 bits + sign, input impedance: >= 1 MOhm
overvoltage protectionwith overvoltage protection
maximum cable distance between devicesshielded cable: <10 m for fast input shielded cable: <100 m for digital input unshielded cable: <50 m for digital input
configurable filtering time0 ms no filter (none) 0.004...0.04 ms bounce filter (latch/event and cumulative filter by step Nx0.5ms (64>=N>=2)) 3...12 ms integrator (none/run/stop)
analogue output range0...20 mA/4...20 mA (> 300 Ohm) for open-circuit -10...10 V/0...10 V (> 2 kOhm) for short-circuit
isolation between channelsnone
absolute accuracy error+/- 0.1 % of full scale cyclic ratio 1...99% for fast output (PWM or PTO mode) 1 % of full scale cyclic ratio 1...99% for fast output (PWM or PTO mode) +/- 5 % of full scale cyclic ratio 10...90% for fast output (PWM or PTO mode) +/- 10 % of full scale cyclic ratio 20...80% for fast output (PWM or PTO mode) +/- 15 % of full scale cyclic ratio 30...70% for fast output (PWM or PTO mode)
sensor power supply15-28.8 V DC >= 15 V, current (state 1): >= 5 mA <= 5 V, current (state 0): <= 1.5 mA 15-28.8 V DC >= 15 V, current (state 1): >= 2.5 mA <= 5 V, current (state 0): <= 1 mA
display resolution320 x 240 pixels QVGA
operating systemMagelis
input/output number2 for fast input, terminal(s): FI0...FI1 2 for fast output, terminal(s): FQ0...FQ1 6 for digital input, terminal(s): DI0...DI5 6 for digital output, terminal(s): DQ0...DQ5
isolation between channels and internal logic500 V DC
software designationSoMachine
view angle horiz x vert60° left 60° right 40° top 60° bottom
processor frequency333 MHz
processor nameCPU RISC
number of common point1 for fast input (HSC mode) 1 for digital input
Okolje
Temperatura okoliškega zraka za delovanje0-50 °C
IP stopnja zaščiteIP20 (rear panel) conforming to IEC 60529 IP65 (front panel) conforming to IEC 60529
Stopnja onesnaženosti2 conforming to IEC 60664
Temperatura okoliškega zraka za skladiščenje-20-60 °C
relative humidity5-85 % without condensation
Nadmorska višina delovanja<= 2000 m
Certifikati izdelkovcULus 508 cULus CSA 22-2 No 142 GOST cUL 1604 Class 1 Division 2 C-Tick KCC
StandardiFCC Class A EN 61131-2 UL 508 IEC 61000-6-2 WEEE directive 2002/96/EC CSA C22.2 No 213 Class I Division 2 RoHS China SJ/T 11363-2006 RoHS compliant ANSI/ISA 12-12-01
NEMA degree of protectionNEMA 4X front panel
environmental characteristiccorrosive gas free
markingCE
storage altitude0-10000 m
maximum pressure800...1114 hPa