Menu
Vaša košarica

ATV212WU22N4C Schneider Electric

ATV212WU22N4C  Schneider Electric
ATV212WU22N4C Schneider Electric

Opis

variable speed drive ATV212 - 2.2kW - 3hp - 480V - 3ph - EMC class C1 - IP55

Tehnične lastnosti

Glavno
Serija izdelkaAltivar 212
Izdelek ali sestavni delvariable speed drive
Kratko ime napraveATV212
[Us] Nazivna napajalna npetost380...480 V - 15...10 %
product destinationasynchronous motors
product specific applicationpumps and fans in HVAC
network number of phases3 phases
line current4.6 A at 380 V 3.7 A at 480 V
motor power kW2.2 kW
assembly stylewith heat sink
EMC filterClass C1 EMC filter integrated
motor power hp3 hp
supply frequency50...60 Hz - 5...5 %
supply voltage limits323-528 V
Komplementarno
network frequency47.5...63 Hz
Višina297 mm
Teža izdelka7.5 kg
local signalling1 LED (red)DC bus energized:
Širina215 mm
Globina192 mm
tightening torque1.3 N.m, 11.5 lb.in (L1/R, L2/S, L3/T) 0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES)
protection typeoverheating protection: drive line supply undervoltage: drive against input phase loss: drive thermal protection: motor motor phase break: motor with PTC probes: motor thermal power stage: drive short-circuit between motor phases: drive input phase breaks: drive overcurrent between output phases and earth: drive overvoltages on the DC bus: drive break on the control circuit: drive against exceeding limit speed: drive line supply overvoltage and undervoltage: drive
operating positionvertical +/- 10 degree
output voltage<= power supply voltage
electrical connectionVIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5-2.5 mm² / AWG 14 L1/R, L2/S, L3/T: terminal 6-6 mm² / AWG 10
transmission rate9600 bps or 19200 bps
type of cablewithout mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC with UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC
specific applicationHVAC
switching frequency6...16 kHz adjustable 12...16 kHz with derating factor
insulation resistance>= 1 mOhm 500 V DC for 1 minute
accuracy+/- 0.6 % (VIA) for a temperature variation 60 °C +/- 0.6 % (VIB) for a temperature variation 60 °C +/- 1 % (FM) for a temperature variation 60 °C
maximum switching current5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R) 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R) 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R) 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R)
discrete output typeconfigurable relay logic: (FLA, FLC) NO - 100000 cycles configurable relay logic: (FLB, FLC) NC - 100000 cycles configurable relay logic: (RY, RC) NO - 100000 cycles
response timeFM 2 ms, tolerance +/- 0.5 ms for analog output(s) FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s) FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s) RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s)
discrete input logicpositive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1) negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1)
acceleration and deceleration rampsautomatic based on the load linear adjustable separately from 0.01 to 3200 s
analogue output typeFM switch-configurable voltage 0...10 V DC, impedance: 7620 Ohm, resolution 10 bits FM switch-configurable current 0...20 mA, impedance: 970 Ohm, resolution 10 bits
physical interface2-wire RS 485
transient overtorque120-120 % of nominal motor torque +/- 10 % for 60 s
torque accuracy+/- 15 %
data format8 bits, 1 stop, odd even or no configurable parity
frequency resolutiondisplay unit: 0.1 Hz analog input: 0.024/50 Hz
connector type1 RJ45 1 open style
analogue input number2
motor slip compensationadjustable automatic whatever the load not available in voltage/frequency ratio motor control
discrete output number2
communication port protocolLonWorks METASYS N2 Modbus BACnet APOGEE FLN
regulation loopadjustable PI regulator
transmission frameRTU
analogue output number1
minimum switching current3 mA at 24 V DC for configurable relay logic
speed range1-10
linearity errorVIA: +/- 0.15 % of maximum value for input VIB: +/- 0.15 % of maximum value for input FM: +/- 0.2 % for output
number of addresses1-247
braking to standstillby DC injection
discrete input typeF programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm RES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm
analogue input typeVIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits VIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits VIB configurable PTC probe: 0...6 probes, impedance: 1500 Ohm VIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bits
supplyinternal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection internal supply: 24 V DC (21-27 V), <200 A, protection type: overload and short-circuit protection
speed accuracy+/- 10 % of nominal slip 0.2 Tn to Tn
sampling duration2 ms +/- 0.5 ms F discrete 2 ms +/- 0.5 ms R discrete 2 ms +/- 0.5 ms RES discrete 3.5 ms +/- 0.5 ms VIA analog 22 ms +/- 0.5 ms VIB analog
option cardcommunication card for LonWorks
IP degree of protectionIP55
isolationelectrical between power and control
type of polarizationno impedance
prospective line Isc5 kA
asynchronous motor control profilevoltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) voltage/frequency ratio, 5 points voltage/frequency ratio - Energy Saving, quadratic U/f flux vector control without sensor, standard voltage/frequency ratio, 2 points
dielectric strength3535 V DC between earth and power terminals 5092 V DC between control and power terminals
apparent power3.9 kVA at 380 V
speed drive output frequency0.5-200 Hz
communication servicewrite single register (06) read holding registers (03) 2 words maximum monitoring inhibitable write multiple registers (16) 2 words maximum read device identification (43) time out setting from 0.1 to 100 s
maximum transient current5.6 A for 60 s
continuous output current5.1 A at 380 V 5.1 A at 460 V
nominal switching frequency12 kHz
Okolje
Temperatura okoliškega zraka za delovanje-10-40 °C (without) 40-50 °C (with derating factor)
IP stopnja zaščiteIP55 conforming to EN/IEC 61800-5-1 IP55 conforming to EN/IEC 60529
Stopnja onesnaženosti3 conforming to IEC 61800-5-1
Temperatura okoliškega zraka za skladiščenje-25-70 °C
relative humidity5-95 % without condensation conforming to IEC 60068-2-3 5-95 % without dripping water conforming to IEC 60068-2-3
Nadmorska višina delovanja1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 1000 m without
Certifikati izdelkovNOM 117 CSA C-Tick UL
StandardiEN 61800-5-1 IEC 61800-3 environments 2 category C2 IEC 61800-3 environments 2 category C3 IEC 61800-3 category C1 EN 61800-3 environments 2 category C1 EN 61800-3 environments 1 category C2 IEC 61800-5-1 EN 61800-3 environments 1 category C3 EN 61800-3 environments 2 category C2 IEC 61800-3 environments 1 category C3 EN 61800-3 EN 61800-3 environments 1 category C1 EN 55011 group 1 class B EN 61800-3 category C1 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 2 category C1 IEC 61800-3 IEC 61800-3 environments 1 category C2 EN 61800-3 environments 2 category C3
Odporno proti udarcu15 gn for 11 ms conforming to IEC 60068-2-27
Odpornost proti vibracijam1.5 mm (f= 3-13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f= 13-200 Hz) conforming to EN/IEC 60068-2-8
Elektromagnetna kompatibilnostelectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 voltage dips and interruptions immunity test conforming to IEC 61000-4-11
environmental characteristicclasses 3C1 conforming to IEC 60721-3-3 classes 3S2 conforming to IEC 60721-3-3
markingCE
noise level48 dB conforming to 86/188/EEC