ATV212WU22N4C Schneider Electric

ATV212WU22N4C Schneider Electric
Opis
variable speed drive ATV212 - 2.2kW - 3hp - 480V - 3ph - EMC class C1 - IP55
Tehnične lastnosti
| Glavno | |
| Serija izdelka | Altivar 212 |
| Izdelek ali sestavni del | variable speed drive |
| Kratko ime naprave | ATV212 |
| [Us] Nazivna napajalna npetost | 380...480 V - 15...10 % |
| product destination | asynchronous motors |
| product specific application | pumps and fans in HVAC |
| network number of phases | 3 phases |
| line current | 4.6 A at 380 V 3.7 A at 480 V |
| motor power kW | 2.2 kW |
| assembly style | with heat sink |
| EMC filter | Class C1 EMC filter integrated |
| motor power hp | 3 hp |
| supply frequency | 50...60 Hz - 5...5 % |
| supply voltage limits | 323-528 V |
| Komplementarno | |
| network frequency | 47.5...63 Hz |
| Višina | 297 mm |
| Teža izdelka | 7.5 kg |
| local signalling | 1 LED (red)DC bus energized: |
| Širina | 215 mm |
| Globina | 192 mm |
| tightening torque | 1.3 N.m, 11.5 lb.in (L1/R, L2/S, L3/T) 0.6 N.m (VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES) |
| protection type | overheating protection: drive line supply undervoltage: drive against input phase loss: drive thermal protection: motor motor phase break: motor with PTC probes: motor thermal power stage: drive short-circuit between motor phases: drive input phase breaks: drive overcurrent between output phases and earth: drive overvoltages on the DC bus: drive break on the control circuit: drive against exceeding limit speed: drive line supply overvoltage and undervoltage: drive |
| operating position | vertical +/- 10 degree |
| output voltage | <= power supply voltage |
| electrical connection | VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES: terminal 2.5-2.5 mm² / AWG 14 L1/R, L2/S, L3/T: terminal 6-6 mm² / AWG 10 |
| transmission rate | 9600 bps or 19200 bps |
| type of cable | without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 90 °C / XLPE/EPR without mounting kit: 1 wire(s)IEC cable at 45 °C, copper 70 °C / PVC with UL Type 1 kit: 3 wire(s)UL 508 cable at 40 °C, copper 75 °C / PVC |
| specific application | HVAC |
| switching frequency | 6...16 kHz adjustable 12...16 kHz with derating factor |
| insulation resistance | >= 1 mOhm 500 V DC for 1 minute |
| accuracy | +/- 0.6 % (VIA) for a temperature variation 60 °C +/- 0.6 % (VIB) for a temperature variation 60 °C +/- 1 % (FM) for a temperature variation 60 °C |
| maximum switching current | 5 A at 250 V AC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R) 5 A at 30 V DC on resistive load - cos phi = 1 - L/R = 0 ms (FL, R) 2 A at 250 V AC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R) 2 A at 30 V DC on inductive load - cos phi = 0.4 - L/R = 7 ms (FL, R) |
| discrete output type | configurable relay logic: (FLA, FLC) NO - 100000 cycles configurable relay logic: (FLB, FLC) NC - 100000 cycles configurable relay logic: (RY, RC) NO - 100000 cycles |
| response time | FM 2 ms, tolerance +/- 0.5 ms for analog output(s) FLA, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s) FLB, FLC 7 ms, tolerance +/- 0.5 ms for discrete output(s) RY, RC 7 ms, tolerance +/- 0.5 ms for discrete output(s) |
| discrete input logic | positive logic (source) (F, R, RES), <= 5 V (state 0), >= 11 V (state 1) negative logic (sink) (F, R, RES), >= 16 V (state 0), <= 10 V (state 1) |
| acceleration and deceleration ramps | automatic based on the load linear adjustable separately from 0.01 to 3200 s |
| analogue output type | FM switch-configurable voltage 0...10 V DC, impedance: 7620 Ohm, resolution 10 bits FM switch-configurable current 0...20 mA, impedance: 970 Ohm, resolution 10 bits |
| physical interface | 2-wire RS 485 |
| transient overtorque | 120-120 % of nominal motor torque +/- 10 % for 60 s |
| torque accuracy | +/- 15 % |
| data format | 8 bits, 1 stop, odd even or no configurable parity |
| frequency resolution | display unit: 0.1 Hz analog input: 0.024/50 Hz |
| connector type | 1 RJ45 1 open style |
| analogue input number | 2 |
| motor slip compensation | adjustable automatic whatever the load not available in voltage/frequency ratio motor control |
| discrete output number | 2 |
| communication port protocol | LonWorks METASYS N2 Modbus BACnet APOGEE FLN |
| regulation loop | adjustable PI regulator |
| transmission frame | RTU |
| analogue output number | 1 |
| minimum switching current | 3 mA at 24 V DC for configurable relay logic |
| speed range | 1-10 |
| linearity error | VIA: +/- 0.15 % of maximum value for input VIB: +/- 0.15 % of maximum value for input FM: +/- 0.2 % for output |
| number of addresses | 1-247 |
| braking to standstill | by DC injection |
| discrete input type | F programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm R programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm RES programmable 24 V DC, with level 1 PLC, impedance: 4700 Ohm |
| analogue input type | VIA switch-configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits VIB configurable voltage: 0...10 V DC 24 V max, impedance: 30000 Ohm, resolution 10 bits VIB configurable PTC probe: 0...6 probes, impedance: 1500 Ohm VIA switch-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 10 bits |
| supply | internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 A, protection type: overload and short-circuit protection internal supply: 24 V DC (21-27 V), <200 A, protection type: overload and short-circuit protection |
| speed accuracy | +/- 10 % of nominal slip 0.2 Tn to Tn |
| sampling duration | 2 ms +/- 0.5 ms F discrete 2 ms +/- 0.5 ms R discrete 2 ms +/- 0.5 ms RES discrete 3.5 ms +/- 0.5 ms VIA analog 22 ms +/- 0.5 ms VIB analog |
| option card | communication card for LonWorks |
| IP degree of protection | IP55 |
| isolation | electrical between power and control |
| type of polarization | no impedance |
| prospective line Isc | 5 kA |
| asynchronous motor control profile | voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) voltage/frequency ratio, 5 points voltage/frequency ratio - Energy Saving, quadratic U/f flux vector control without sensor, standard voltage/frequency ratio, 2 points |
| dielectric strength | 3535 V DC between earth and power terminals 5092 V DC between control and power terminals |
| apparent power | 3.9 kVA at 380 V |
| speed drive output frequency | 0.5-200 Hz |
| communication service | write single register (06) read holding registers (03) 2 words maximum monitoring inhibitable write multiple registers (16) 2 words maximum read device identification (43) time out setting from 0.1 to 100 s |
| maximum transient current | 5.6 A for 60 s |
| continuous output current | 5.1 A at 380 V 5.1 A at 460 V |
| nominal switching frequency | 12 kHz |
| Okolje | |
| Temperatura okoliškega zraka za delovanje | -10-40 °C (without) 40-50 °C (with derating factor) |
| IP stopnja zaščite | IP55 conforming to EN/IEC 61800-5-1 IP55 conforming to EN/IEC 60529 |
| Stopnja onesnaženosti | 3 conforming to IEC 61800-5-1 |
| Temperatura okoliškega zraka za skladiščenje | -25-70 °C |
| relative humidity | 5-95 % without condensation conforming to IEC 60068-2-3 5-95 % without dripping water conforming to IEC 60068-2-3 |
| Nadmorska višina delovanja | 1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 1000 m without |
| Certifikati izdelkov | NOM 117 CSA C-Tick UL |
| Standardi | EN 61800-5-1 IEC 61800-3 environments 2 category C2 IEC 61800-3 environments 2 category C3 IEC 61800-3 category C1 EN 61800-3 environments 2 category C1 EN 61800-3 environments 1 category C2 IEC 61800-5-1 EN 61800-3 environments 1 category C3 EN 61800-3 environments 2 category C2 IEC 61800-3 environments 1 category C3 EN 61800-3 EN 61800-3 environments 1 category C1 EN 55011 group 1 class B EN 61800-3 category C1 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 2 category C1 IEC 61800-3 IEC 61800-3 environments 1 category C2 EN 61800-3 environments 2 category C3 |
| Odporno proti udarcu | 15 gn for 11 ms conforming to IEC 60068-2-27 |
| Odpornost proti vibracijam | 1.5 mm (f= 3-13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f= 13-200 Hz) conforming to EN/IEC 60068-2-8 |
| Elektromagnetna kompatibilnost | electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 voltage dips and interruptions immunity test conforming to IEC 61000-4-11 |
| environmental characteristic | classes 3C1 conforming to IEC 60721-3-3 classes 3S2 conforming to IEC 60721-3-3 |
| marking | CE |
| noise level | 48 dB conforming to 86/188/EEC |




