Menu
Vaša košarica

CA3KN31JD Schneider Electric

CA3KN31JD  Schneider Electric
CA3KN31JD Schneider Electric

Opis

TeSys K control relay - 3 NO + 1 NC - = 690 V - 12 V DC standard coil

Tehnične lastnosti

Glavno
Serija izdelkaTeSys K control relay
Izdelek ali sestavni delcontrol relay
product nameTeSys CAK
utilisation categoryDC-13 AC-15
Skupina izdelkovTeSys
Kratko ime napraveCA3K
[Uc] Krmilna napetost12 V DC
[Ue] rated operational voltage<= 690 V <= 400 Hz
control circuit typeDC standard
contactor applicationcontrol circuit
pole contact composition3 NO + 1 NC
Komplementarno
Višina58 mm
mounting supportplate rail
Teža izdelka0.225 kg
Povezave - terminaliscrew clamp terminals 1 cable(s) 1.5-4 mm²solid screw clamp terminals 2 cable(s) 1.5-4 mm²solid screw clamp terminals 1 cable(s) 0.75-4 mm²flexible with cable end screw clamp terminals 2 cable(s) 0.75-4 mm²flexible without cable end screw clamp terminals 1 cable(s) 0.34-1.5 mm²flexible with cable end screw clamp terminals 2 cable(s) 0.34-1.5 mm²flexible without cable end
[Ui] Nazivna izolacijska trdnost690 V conforming to IEC 60947 750 V conforming to VDE 0110 group C 690 V conforming to BS 5424 600 V conforming to CSA C22.2 No 14
mechanical durability20 Mcycles
Kompatibilnostna kodaCA3K
Širina45 mm
Globina57 mm
tightening torque1.3 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm 1.3 N.m - on screw clamp terminals - with screwdriver Philips No 26 mm
[Ith] conventional free air thermal current10 A (at 50 °C)
maximum operating rate10000 cyc/h
insulation resistance> 10 MOhm
minimum switching current5 mA
Omejitve napetosti regulacijskega vezjaoperational: 0.8...1.15 Uc (at <50 °C) drop-out: 0.1...0.75 Uc (at <50 °C)
heat dissipation3-3 W
Poraba energije pri zadrževanju v W3-3 W at 20 °C
minimum switching voltage17 V
Vklopna moč v W3-3 W (at 20 °C)
associated fuse rating10 A gG conforming to IEC 60947 10 A gG conforming to VDE 0660
operating time10 ms coil de-energisation and NO opening 30...40 ms coil energisation and NO closing 15 ms coil de-energisation and NC closing 25...35 ms coil energisation and NC opening
non overlap distance0.5 mm
Irms rated making capacity110 A conforming to IEC 60947
immunity to microbreaks2 ms
Okolje
Temperatura okoliškega zraka za delovanje-25-50 °C
IP stopnja zaščiteIP2x
Temperatura okoliškega zraka za skladiščenje-50-80 °C
Nadmorska višina delovanja2000 m without
Certifikati izdelkovCSA UL
StandardiBS 5424 IEC 60947 NF C 63-140 VDE 0660
Zaščitna obdelavaTC conforming to IEC 60068
flame retardanceV1 conforming to UL 94 requirement 2 conforming to NF F 16-101 requirement 2 conforming to NF F 16-102
mechanical robustnessvibrations contactor open: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 shocks contactor open: 10 Gn for 11 ms conforming to IEC 60068-2-27 shocks contactor closed: 15 Gn for 11 ms conforming to IEC 60068-2-27