56175 Schneider Electric

56175  Schneider Electric
56175 Schneider Electric

Opis

residual current protection relay, Vigirex RH99M, 30 mA to 30 A, 440 VAC to 525 VAC 50/60 Hz, local manual reset

Tehnične lastnosti

Glavno
Serija izdelkaVigirex
Izdelek ali sestavni delresidual current protection relay
Skupina izdelkovVigirex
Kratko ime napraveRH99M
Združljivost serije/obsega Vigirex RH TOA earth leakage current sensor Vigirex RH A earth leakage current sensor
relay applicationresidual current protection relay
Komplementarno
Višina97 mm
mounting supportDIN rail
9 mm pitches6
Teža izdelka0.3 kg
Povezave - terminaliauxiliary power supply: terminal block cable(s) 0.2-2.5 mm² flexible AWG 24...AWG 12 sensor: screw terminal cable(s) 0.14-1 mm² flexible AWG 26...AWG 16 sensor: screw terminal cable(s) 0.14-1.5 mm² rigid AWG 26...AWG 16 sensor: screw terminal cable(s) 0.25-0.5 mm² flexible AWG 26...AWG 16 voltage presence: screw terminal cable(s) 0.2-2.5 mm² flexible AWG 24...AWG 12 voltage presence: screw terminal cable(s) 0.2-4 mm² rigid AWG 24...AWG 12 voltage presence: screw terminal cable(s) 0.25-2.5 mm² flexible AWG 24...AWG 12 auxiliary power supply: terminal block cable(s) 0.2-2.5 mm² rigid AWG 24...AWG 12 auxiliary power supply: terminal block cable(s) 0.25-2.5 mm² flexible AWG 24...AWG 12 fault: screw terminal cable(s) 0.2-2.5 mm² flexible AWG 24...AWG 12 fault: screw terminal cable(s) 0.2-4 mm² rigid AWG 24...AWG 12 fault: screw terminal cable(s) 0.25-2.5 mm² flexible AWG 24...AWG 12 relay test and fault reset: screw terminal cable(s) 0.14-1 mm² flexible AWG 26...AWG 16 relay test and fault reset: screw terminal cable(s) 0.14-1.5 mm² rigid AWG 26...AWG 16 relay test and fault reset: screw terminal cable(s) 0.25-0.5 mm² flexible AWG 26...AWG 16
wire stripping lengthauxiliary power supply: 7 mm for top connection fault: 8 mm for bottom connection relay test and fault reset: 5 mm for bottom connection sensor: 5 mm for top connection voltage presence: 8 mm for bottom connection
Kompatibilnostna kodaRH99M
Širina54 mm
Globina74 mm
tightening torqueauxiliary power supply: 0.6-0.6 N.m top fault: 0.6-0.6 N.m bottom relay test and fault reset: 0.25-0.25 N.m bottom sensor: 0.25-0.25 N.m top voltage presence: 0.6-0.6 N.m bottom
[Us] rated supply voltage440...525 V AC 50/60 Hz
earth-leakage protection classclass AC class A si
residual earth-leakage time delay adjustment typeinstantaneous 0.03-0.03 A adjustable 9 settings 0.03-30 A 0-4.5 s
[Ithe] conventional enclosed thermal current8 A
power consumption in VA4 VA
overvoltage categoryIV
earthing systemTT IT TN-S
minimum load10 mA at 12 V
mechanical robustnessfire resistance conforming to IEC 60695-2-1 IK protection 2 joules: IK07 conforming to EN 50102 IP protection: IP20 conforming to IEC 60529 IP protection: IP30 conforming to IEC 60529 IP protection: IP40 conforming to IEC 60529 vibrations 13.2...100 Hz: 0.7 g vibrations 2...13.2 Hz: +/- 1 mm
type of measurementearth fault current internal measurement, range: 80...100 %
test functionlocal remote test
tamperproof of settingsprotected by sealable cover
monitoringelectronics (continuous) power supply (continuous) relay/sensor link (continuous)
Okolje
Temperatura okoliškega zraka za delovanje-35-70 °C
Temperatura okoliškega zraka za skladiščenje-55-85 °C
electrical shock protection classclass II
Elektromagnetna kompatibilnostconducted and radiated emissions: , B, conforming to CISPR 11 conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6 electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2 high-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5 low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4 radiated susceptibility: , 3, conforming to IEC 61000-4-3