Earth-leakage relay RH10M - 30 mA - 24 V
Tehnične lastnosti
| Glavno | |
| Serija izdelka | Vigirex |
| Izdelek ali sestavni del | residual current protection relay |
| Skupina izdelkov | Vigirex |
| Kratko ime naprave | RH10M |
| Združljivost serije/obsega | Vigirex RH TOA earth leakage current sensor Vigirex RH A earth leakage current sensor |
| relay application | residual current protection relay |
| Komplementarno | |
| Višina | 97 mm |
| mounting support | DIN rail |
| 9 mm pitches | 6 |
| Teža izdelka | 0.3 kg |
| Povezave - terminali | auxiliary power supply: terminal block cable(s) 0.2-2.5 mm² flexible AWG 24...AWG 12 sensor: screw terminal cable(s) 0.14-1 mm² flexible AWG 26...AWG 16 sensor: screw terminal cable(s) 0.14-1.5 mm² rigid AWG 26...AWG 16 sensor: screw terminal cable(s) 0.25-0.5 mm² flexible AWG 26...AWG 16 voltage presence: screw terminal cable(s) 0.2-2.5 mm² flexible AWG 24...AWG 12 voltage presence: screw terminal cable(s) 0.2-4 mm² rigid AWG 24...AWG 12 voltage presence: screw terminal cable(s) 0.25-2.5 mm² flexible AWG 24...AWG 12 auxiliary power supply: terminal block cable(s) 0.2-2.5 mm² rigid AWG 24...AWG 12 auxiliary power supply: terminal block cable(s) 0.25-2.5 mm² flexible AWG 24...AWG 12 fault: screw terminal cable(s) 0.2-2.5 mm² flexible AWG 24...AWG 12 fault: screw terminal cable(s) 0.2-4 mm² rigid AWG 24...AWG 12 fault: screw terminal cable(s) 0.25-2.5 mm² flexible AWG 24...AWG 12 relay test and fault reset: screw terminal cable(s) 0.14-1 mm² flexible AWG 26...AWG 16 relay test and fault reset: screw terminal cable(s) 0.14-1.5 mm² rigid AWG 26...AWG 16 relay test and fault reset: screw terminal cable(s) 0.25-0.5 mm² flexible AWG 26...AWG 16 |
| wire stripping length | auxiliary power supply: 7 mm for top connection fault: 8 mm for bottom connection relay test and fault reset: 5 mm for bottom connection sensor: 5 mm for top connection voltage presence: 8 mm for bottom connection |
| Kompatibilnostna koda | RH10M |
| Širina | 54 mm |
| Globina | 74 mm |
| tightening torque | auxiliary power supply: 0.6-0.6 N.m top fault: 0.6-0.6 N.m bottom relay test and fault reset: 0.25-0.25 N.m bottom sensor: 0.25-0.25 N.m top voltage presence: 0.6-0.6 N.m bottom |
| [Us] rated supply voltage | 12...24 V AC 50/60 Hz 12...48 V DC |
| earth-leakage protection class | class A si class AC |
| residual earth-leakage time delay adjustment type | instantaneous 0.03-0.03 A |
| [Ithe] conventional enclosed thermal current | 8 A |
| power consumption in VA | 4 VA |
| overvoltage category | IV |
| earthing system | IT TT TN-S |
| minimum load | 10 mA at 12 V |
| mechanical robustness | fire resistance conforming to IEC 60695-2-1 IK protection 2 joules: IK07 conforming to EN 50102 IP protection: IP20 conforming to IEC 60529 IP protection: IP30 conforming to IEC 60529 IP protection: IP40 conforming to IEC 60529 vibrations 13.2...100 Hz: 0.7 g vibrations 2...13.2 Hz: +/- 1 mm |
| type of measurement | earth fault current internal measurement, range: 80...100 % |
| test function | remote test local |
| tamperproof of settings | protected by sealable cover |
| monitoring | electronics (continuous) power supply (continuous) relay/sensor link (continuous) |
| Okolje | |
| Temperatura okoliškega zraka za delovanje | -35-70 °C |
| Temperatura okoliškega zraka za skladiščenje | -55-85 °C |
| electrical shock protection class | class II |
| Elektromagnetna kompatibilnost | conducted and radiated emissions: , B, conforming to CISPR 11 conducted radio-frequency immunity test: , 3, conforming to IEC 61000-4-6 electrostatic discharge immunity test: , 4, conforming to IEC 61000-4-2 high-energy conducted susceptibility: , 4, conforming to IEC 61000-4-5 low-energy conducted susceptibility: , 4, conforming to IEC 61000-4-4 radiated susceptibility: , 3, conforming to IEC 61000-4-3 |