RE22R2MJU Schneider Electric

RE22R2MJU Schneider Electric
Opis
Multifunction Timer Relay - 12V AC/DC - 2 C/O
Tehnične lastnosti
| Glavno | |
| Serija izdelka | Zelio Time |
| Izdelek ali sestavni del | modular timing relay |
| Kratko ime naprave | RE22 |
| nominal output current | 8 A |
| discrete output type | relay |
| Komplementarno | |
| mounting support | 35 mm DIN rail conforming to EN/IEC 60715 |
| Teža izdelka | 0.09 kg |
| Povezave - terminali | screw terminals, 2 x 1.5 mm² with cable end screw terminals, 2 x 2.5 mm² without cable end |
| control type | rotary knob front panel |
| electrical durability | 100000 cycles for resistive load, 8 A at 250 V, AC |
| mechanical durability | 10000000 cycles |
| [Uimp] rated impulse withstand voltage | 5 kV for 1.2-50 µs conforming to IEC 60664-1 5 kV conforming to IEC 61812-1 |
| Širina | 22.5 mm |
| tightening torque | 0.6-1 N.m conforming to IEC 60947-1 |
| [Us] rated supply voltage | 12 V AC/DC |
| contacts type and composition | 1 C/O timed contact 1 C/O timed or instantaneous contact 2 C/O |
| breaking capacity | 2000 VA |
| housing material | self-extinguishing |
| repeat accuracy | +/- 0.5 % conforming to IEC 61812-1 |
| maximum delay response | 100 ms |
| status LED | LED green (flashing) for timing in progress LED green (steady) for power ON LED yellow for relay energised |
| insulation resistance | 100 MOhm at 500 V DC conforming to IEC 60664-1 |
| mounting position | any position in relation to normal vertical mounting plane |
| power consumption in W | 0.5 W at 12 V DC |
| power consumption in VA | 1.2-1.2 VA at 12 V AC |
| safety reliability data | B10d = 190000 MTTFd = 205.4 years |
| supply frequency | 50...60 Hz +/- 5 % |
| time delay range | 1...10 min 6...60 min 0.1...1 s 6...60 s 1...10 s 1...10 h 10...100 h |
| maximum switching current | 8 mA |
| minimum switching current | 10 mA at 5 V |
| maximum switching voltage | 250 V |
| setting accuracy of time delay | +/- 10 % of full scale at 25 °C conforming to IEC 61812-1 |
| voltage range | 0.9...1.2 Us |
| reset time | 120 ms on de-energisation |
| voltage drift | +/- 0.2 %/V |
| functionality | multifunction |
| temperature drift | +/- 0.05 %/°C |
| time delay type | A, Ac, At, B, Bw, C, D, Di, H, Ht B C Di Ht Bw Ac H At A D |
| immunity to microbreaks | 10 ms |
| minimum pulse duration | 30 ms 100 ms under load |
| Okolje | |
| Temperatura okoliškega zraka za delovanje | -20-60 °C |
| IP stopnja zaščite | IP40 housing: conforming to IEC 60529 IP20 terminal block: conforming to IEC 60529 IP40 front face: conforming to IEC 60529 |
| Temperatura okoliškega zraka za skladiščenje | -30-60 °C |
| relative humidity | 93-93 %, without condensation conforming to IEC 60068-2-30 |
| Certifikati izdelkov | CSA cULus China RoHS CE EAC GL CCC RCM |
| Standardi | EN 61000-6-1 IEC 61812-1 EN 61000-6-4 EN 61000-6-3 EN 61000-6-2 |
| Odporno proti udarcu | 15 gn for 11 ms conforming to IEC 60068-2-27 |
| Odpornost proti vibracijam | 20 m/s² (f= 10-150 Hz) conforming to IEC 60068-2-6 |
| Elektromagnetna kompatibilnost | electrostatic discharge immunity test - test level: 6 kV level 3 (contact discharge) conforming to EN/IEC 61000-4-2 immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11 conducted and radiated emissions class B conforming to EN 55022 electrostatic discharge immunity test - test level: 8 kV level 3 (air discharge) conforming to EN/IEC 61000-4-2 fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 fast transients immunity test - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4 surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5 radiated radio-frequency electromagnetic field immunity test - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6 electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3 immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11 |
| directives | 2006/95/EC - low voltage directive 2004/108/EC - electromagnetic compatibility |
| dielectric strength | 2.5 kV for 1 mA/1 minute at 50 Hz conforming to IEC 61812-1 |