circuit breaker Compact NSX160B, 25 kA at 415 VAC, Micrologic 5.2 A trip unit 100 A, 4 poles 4d

Tehnične lastnosti

Glavno
[In] rated current100 A at 40 °C
Serija izdelkaNSX100...250
network typeAC
breaking capacity codeB 25 kA 415 V AC
Izdelek ali sestavni delcircuit breaker
product nameCompact NSX
utilisation categorycategory A
Skupina izdelkovCompact
breaking capacity15 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA Icu at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolationyes conforming to EN 60947-2 yes conforming to IEC 60947-2
Opis polov4P
Aplikacija napravedistribution
Kratko ime napraveCompact NSX160B
trip unit technologyelectronic
network frequency50/60 Hz
[Ics] rated service breaking capacity20 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2 25 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2 15 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
trip unit nameMicrologic 5.2 A
protected poles description3t + N/2 4t 3t 3t + 1.6 N
neutral positionleft
[Ue] rated operational voltage690 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage8 kV
[Ui] rated insulation voltage800 V AC 50/60 Hz
pollution degree3 conforming to IEC 60664-1
trip unit protection functionsLSI
Komplementarno
Višina161 mm
mounting supportbackplate
Teža izdelka2.6 kg
control typetoggle
mounting modefixed
electrical durability10000 cycles 440 V In/2 conforming to IEC 60947-2 15000 cycles 690 V In/2 conforming to IEC 60947-2 20000 cycles 440 V In conforming to IEC 60947-2 7500 cycles 690 V In conforming to IEC 60947-2
mechanical durability40000 cycles
Kompatibilnostna kodaNSX160
local signallingLED 105 % Ir LED 90 % Ir LED ready
Širina140 mm
Globina86 mm
long time pick-up adjustment type Iradjustable
upside connectionfront
downside connectionfront
protection typeL : for overload protection (long time) S : for short time short-circuit protection I : for instantaneous short-circuit protection
connection pitch35 mm
instantaneous pick-up adjustment range1.5...15 x In
long time delay adjustment typeadjustable
instantaneous pick-up adjustment type Iiadjustable
neutral protection setting0.5 x Ir (3t + N/2) 1 x Ir (4t) 1.6 x Ir (3t + OSN) no protection (3t)
long time pick-up adjustment range40...100 A
display typeLCD display
trip unit rating100-100 A at 40 °C
thermal memory20 minutes before and after tripping
[tr] long-time delay adjustment range15-400 s at 1.5 x Ir 0.35-11 s at 7.2 x Ir 0.5-16 s at 6 x Ir
type of measurementammeter
zone selective interlocking ZSIwith
short-time delay adjustment typeadjustable
[tsd] short-time delay adjustment range0-0.4 s
[Isd] short-time pick-up adjustment range1.5...10 x Ir
short-time pick-up adjustment type Isdadjustable
communication of dataenergy metering instantaneous and demand values time-stamped histories and event tables protection and alarm settings maximeters/minimeters demand current and power maintenance indicators power quality
electrical data recordingmaintenance indicators
Okolje
Temperatura okoliškega zraka za delovanje-35-70 °C
IP stopnja zaščiteIP40 conforming to IEC 60529
Temperatura okoliškega zraka za skladiščenje-55-85 °C
overvoltage categoryclass II
IK stopnja zaščiteIK07 conforming to IEC 62262
Certifikati izdelkovEAC Marine CCC
StandardiEN/IEC 60947
electrical shock protection classclass II