Menu
Vaša košarica

LC1K12004Q7 Schneider

LC1K12004Q7  Schneider
LC1K12004Q7 Schneider

Opis

TeSys K contactor - 4P (4 NO) - AC-1 = 440 V 20 A - 380...400 V AC coil

Tehnične lastnosti

Glavno
Serija izdelkaTeSys K
Izdelek ali sestavni delcontactor
product nameTeSys K
Skupina izdelkovTeSys
Aplikacija napravecontrol
contactor applicationresistive load
Komplementarno
Kompatibilnostna kodaLC1K
[Ith] conventional free air thermal current20 A (at 50 °C) for power circuit
rated breaking capacity110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947
[Ie] rated operational current20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit 16 A (at <70 °C) at 690 V AC AC-1 for power circuit
[Uc] control circuit voltage380...400 V AC 50/60 Hz
maximum operating rate3600 cyc/h
poles description4P
overvoltage categoryIII
Omejitve napetosti regulacijskega vezjaoperational: 0.8...1.15 Uc (at <50 °C) drop-out: 0.2...0.75 Uc (at <50 °C)
Inrush power in VA30-30 VA (at 20 °C)
Hold-in power consumption in VA4.5-4.5 VA (at 20 °C)
heat dissipation1.3-1.3 W
signalling circuit frequency<= 400 Hz
average impedance3 mOhm - Ith 20 A 50 Hz for power circuit
associated fuse rating25 A gG at <= 440 V for power circuit 25 A aM for power circuit
operating time10...20 ms coil de-energisation and NO opening 10...20 ms coil energisation and NO closing
utilisation categoryAC-1
mechanical robustnessshocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6
control circuit typeAC at 50/60 Hz
safety reliability levelB10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Irms rated making capacity144 A AC for power circuit conforming to NF C 63-110 144 A AC for power circuit conforming to IEC 60947
pole contact composition4 NO
Okolje
Nadmorska višina delovanja2000 m without
Certifikati izdelkovCSA UL
Zaščitna obdelavaTC conforming to IEC 60068 TC conforming to DIN 50016
flame retardanceV1 conforming to UL 94 requirement 2 conforming to NF F 16-101 requirement 2 conforming to NF F 16-102