Menu
Vaša košarica

ATV340D37N4E Schneider Electric

ATV340D37N4E  Schneider Electric
ATV340D37N4E Schneider Electric

Opis

variable speed drive - 37kW- 400V - 3 phases - ATV340 Ethernet

Tehnične lastnosti

Glavno
Serija izdelkaAltivar Machine ATV340
Izdelek ali sestavni delvariable speed drive
Aplikacija napravemachine
Kratko ime napraveATV340
[Us] Nazivna napajalna npetost380...480 V - 15...10 %
product destinationsynchronous motors asynchronous motors
variantstandard version
IP degree of protectionIP20 conforming to IEC 61800-5-1 IP20 conforming to IEC 60529
mounting modewall mount
network number of phases3 phases
line current79.8 A at 380 V with internal line choke (normal duty) 69.1 A at 480 V with internal line choke (normal duty) 67.1 A at 380 V with internal line choke (heavy duty) 59 A at 480 V with internal line choke (heavy duty) 67.1 A 59.0 A
asynchronous motor control profileoptimized torque mode variable torque standard constant torque standard
apparent power57.4 kVA at 480 V (normal duty) 49.1 kVA at 480 V (heavy duty)
motor power kW45 kW for normal duty 37 kW for heavy duty
switching frequency2...16 kHz adjustable 4...16 kHz with derating factor
maximum transient current105.6 A during 60 s (normal duty) 105.6 A during 2 s (normal duty) 111.8 A during 60 s (heavy duty) 111.8 A during 2 s (heavy duty)
nominal switching frequency4 kHz
EMC filterintegrated with 50 m conforming to EN/IEC 61800-3 category C2 integrated with 150 m conforming to EN/IEC 61800-3 category C3
motor power hp60 hp for normal duty 50 hp for heavy duty
prospective line Isc50 kA
speed drive output frequency0.1-500 Hz
type of coolingforced convection
continuous output current88 A at 4 kHz for normal duty 74.5 A at 4 kHz for heavy duty
safety functionSTO (safe torque off) SIL 3
supply frequency50...60 Hz +/- 5 %
synchronous motor control profilereluctance motor permanent magnet motor
degree of protectionUL type 1 conforming to UL 508C
Komplementarno
Višina660 mm
Teža izdelka28.4 kg
local signallinglocal diagnostic: 3 LED (mono/dual colour) embedded communication status: 5 LED (dual colour) communication module status: 2 LED (dual colour) presence of voltage: 1 LED (red)
Širina213 mm
Globina262 mm
protection typethermal protection: motor safe torque off: motor motor phase loss: motor thermal protection: drive safe torque off: drive overheating: drive overcurrent: drive output overcurrent between motor phase and earth: drive output overcurrent between motor phases: drive short-circuit between motor phase and earth: drive short-circuit between motor phases: drive motor phase loss: drive DC Bus overvoltage: drive line supply overvoltage: drive line supply undervoltage: drive input supply loss: drive exceeding limit speed: drive break on the control circuit: drive
output voltage<= power supply voltage
electrical connectioncontrol: screw terminal0.75...1.5 mm²/AWG 18...AWG 16 line side: screw terminal35...50 mm²/AWG 2...AWG 1 DC bus: screw terminal35...50 mm²/AWG 3...AWG 1 motor: screw terminal50 mm²/AWG 1
transmission rate4800 bps, 9600 bps, 19200 bps, 38.4 Kbps for Modbus serial 10/100 Mbit/s for Ethernet IP/Modbus TCP
accuracy+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
maximum switching currentrelay output R1 on resistive load, cos phi = 1 : 3 A at 250 V AC relay output R1 on resistive load, cos phi = 1 : 3 A at 30 V DC relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC relay output R1 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC relay output R2, R3 on resistive load, cos phi = 1 : 5 A at 250 V AC relay output R2, R3 on resistive load, cos phi = 1 : 5 A at 30 V DC relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC relay output R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
discrete input logicpositive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1) positive logic (source) (DI1...DI8), < 5 V (state 0), > 11 V (state 1) negative logic (sink) (DI1...DI8), > 16 V (state 0), < 10 V (state 1) positive logic (source) (DI7, DI8), < 0.6 V (state 0), > 2.5 V (state 1) 16 preset speeds
acceleration and deceleration rampslinear adjustable separately from 0.01...9999 s S, U or customized
analogue output typesoftware-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits software-configurable current AQ1, AQ2: 0...20 mA impedance 500 Ohm, resolution 10 bits
physical interface2-wire RS 485 for Modbus serial
data format8 bits, configurable odd, even or no parity for Modbus serial
frequency resolutiondisplay unit: 0.1 Hz analog input: 0.012/50 Hz
connector type connector(s)1 x RJ45, Modbus serial on front face connector(s)1 x RJ45, Modbus serial for HMI on front face connector(s)2 x RJ45, Ethernet IP/Modbus TCP on front face
analogue input number3
motor slip compensationadjustable can be suppressed automatic whatever the load not available in permanent magnet motor law
discrete output number2
communication port protocolModbus TCP Modbus serial Ethernet/IP
transmission frameRTU for Modbus serial
analogue output number2
minimum switching currentrelay output R1, R2, R3: 5 mA at 24 V DC
method of accessslave Modbus RTU slave Modbus TCP
discrete input number10
linearity errorAI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
number of addresses1-247 for Modbus serial
braking to standstillby DC injection
discrete input typeSTOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm DI7, DI8 programmable as pulse input: 0-30 kHz, 24 V DC (<= 30 V) DI1...DI8 programmable, 24 V DC (<= 30 V), impedance: 4.4 kOhm
analogue input typeAI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 31.5 kOhm, resolution 12 bits AI1, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits AI1, AI3 software-configurable temperature probe or water level sensor
supplyexternal supply for digital inputs: 24 V DC (19-30 V), <1.25 mA, protection type: overload and short-circuit protection internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection internal supply for digital inputs and STO: 24 V DC (21-27 V), <200 mA, protection type: overload and short-circuit protection
sampling duration2 ms +/- 0.5 ms (DI1...DI8) - discrete input 5 ms +/- 1 ms (DI7, DI8) - pulse input 1 ms +/- 1 ms (AI1, AI2, AI3) - analog input 5 ms +/- 1 ms (AQ1, AQ2) - analog output
option cardslot GP-X: digital and analog I/O extension module slot GP-X: output relay extension module slot GP-ENC: 5/12 V digital encoder interface module slot GP-ENC: analog encoder interface module slot GP-ENC: resolver encoder interface module
exchange modehalf duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
relay output number3
relay output typeconfigurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles configurable relay logic R2: sequence relay NO electrical durability 100000 cycles configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
input compatibilitySTOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2 DI1...DI8: discrete input level 1 PLC conforming to EN/IEC 61131-2 DI7, DI8: pulse input level 1 PLC conforming to IEC 65A-68
refresh timerelay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
type of polarizationno impedance for Modbus serial
power range30-50 kW at 380-440 V 3 phases 30-50 kW at 480-500 V 3 phases
motor starter typevariable speed drive
permissible temporary current boost1.5 x In during 60 s (heavy duty) 1.2 x In during 60 s (normal duty)
input/output typelogic output DQ-: 0-1 kHz, <= 30 V DC, 100 mA logic output DQ+: 0-1 kHz, <= 30 V DC, 100 mA programmable as pulse output DQ+: 0-30 kHz, <= 30 V DC, 20 mA
Okolje
Temperatura okoliškega zraka za delovanje50-60 °C with current derating (heavy duty) 40-60 °C with current derating (normal duty) -15-50 °C without current derating (heavy duty) -15-40 °C without current derating (normal duty)
IP stopnja zaščiteIP20
Stopnja onesnaženosti2 conforming to EN/IEC 61800-5-1
Temperatura okoliškega zraka za skladiščenje-40-70 °C
relative humidity5-95 % without condensation conforming to IEC 60068-2-3
Nadmorska višina delovanja<= 1000 m without 1000...4800 m with current derating 1 % per 100 m
Certifikati izdelkovCSA UL REACH TÜV
Standardi UL 508C EN/IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 EN/IEC 61800-3 EN/IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
Odporno proti udarcu15 gn for 11 ms conforming to IEC 60068-2-27
Odpornost proti vibracijam1.5 mm peak to peak (f= 2-13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13-200 Hz) conforming to IEC 60068-2-6
Elektromagnetna kompatibilnostelectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
environmental characteristicchemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
operating positionvertical +/- 10 degree
markingCE
noise level63.5 dB conforming to 86/188/EEC
insulation resistance> 1 MOhm 500 V DC for 1 minute to earth
power dissipation in Wnatural convection: 90 W at 380 V, switching frequency 4 kHz (heavy duty) forced convection: 796 W at 380 V, switching frequency 4 kHz (heavy duty) natural convection: 105 W at 380 V, switching frequency 4 kHz (normal duty) forced convection: 943 W at 380 V, switching frequency 4 kHz (normal duty)
volume of cooling air240 m3/h
isolationbetween power and control terminals